554835
17
Zoom out
Zoom in
Previous page
1/22
Next page
Installation manual: Oasis security system JA-80K - 17 - MKE51801
of the remote control are pressed
simultaneously, they will trigger a panic alarm
a detector – the PG output copies the status of
the detector or it generates a pulsed switching
event when the detector is triggered. The
detector also effects the control panel which
responds with a natural reaction. Only one
detector should be programmed to a PG output
ON/OFF reaction and should not be combined
with keyfob or keypad control as the detector
repeats its status every 9 minutes and it would
override the signal from the keypad or keyfob.
9
Set/unset Toggles the system status
SET,UNSET,SET,UNSET etc
12.41. Code/card reactions and section assignment
The following sequence programs the features of access codes
or cards:
62 nn r s
where: nn is the user position from 01 to 50
r is the reaction index from 0 to 9 – see Table 2
s is the section 1 = A, 2 = B, 3 = C (only has an
effect in a split system – except for the PG
output control reaction)
Guidance on assigning codes or cards to sections:
In partial setting (arming) mode assigning codes or cards to sections
has no effect (except for the PG output control reaction). If anything in the
system is set and a card/code is used, the system will then be unset, and
if all sections are unset then the whole system will be set by a card/code.
Partial setting keys A and B on the keypad can be programmed to be
followed by a valid access code if required (see 12.13).
For a split system, a code assigned to section:
A controls section A
B controls section B
C controls section A, B and C.
If the system is not split then the assignment of codes/cards to
sections has no effect, but the s parameter must be entered in the
programming section. Enter s=3 if splitting is not desired.
Guidance on code/card reactions:
If a code/card has a natural reaction, i.e. r=1, then its reaction is
set,unset,set etc. (the same as reaction r=9 in table 2).
A code/card can also have an alarm reaction designated to it, similar
to detectors.
Factory default setting: all codes/cards from 01 to 50 have a
natural reaction (set/unset) and are assigned to section C.
12.42. Enrollment by keying in production codes
This sequence allow the enrollment of devices by keying in their
production codes:
60 nn xx..x
where: nn is the address of the device from 01 to 50
xx...x is the production code of the device (the last
eight digits of the bar code, see the label on
the PCB inside the device)
Notes:
If the address nn is already occupied, the current device will be
erased, and the new device will then be enrolled instead.
If a device with production code xx…x has already been enrolled to
another address in the past, and if the device is now enrolled to a new
address, then it will be moved to the new address, releasing the old
address.
If you enter nn = 01 or 02, the device will enroll instead of the
corresponding hard-wired input in the control panel (the terminal will
be disabled).
If eight zeros are entered as a production code, the device already
assigned to the address nn will be erased
12.43. Automatic setting/unsetting schedule
This can be used to program an automatic sequence of daily
setting/unsetting events. Up to 10 daily events can be
programmed. Events will occur every day of the week:
64 n a hh mm
where:
n is the event number from 0 to 9
a is the type of event from 0 to 6 (see the following
table)
hh hours (time of event)
mm minutes (time of event)
Erase the automatic schedule setting by : 64 n 0
* the same event in an unsplit system
** only possible if partial setting (arming) is programmed (see 12.24)
Notes:
The automatic setting/unsetting event schedule can also be
programmed in maintenance mode.
If automatic event scheduling is not used for setting/unsetting control
and the system is not split, then it can be programmed as a daily
timer to switch equipment connected to the PGY output on and off at
the desired daily times. To do this, split the system (see 12.24) but do
not enroll any detectors to section B (keeping this section empty).
Then program the PGY output to be triggered by the setting (arming)
of section B (see 12.5) and program the automatic daily event
schedule (with a=4) to set/unset the empty section B which will then
switch the PGY output on and off at the required times every day.
Factory default setting: All automatic events switched off.
12.44. Changing the service code.
To change the service code enter:
5 NC NC
where: NC = new code (4 digits), the new code has to be
entered twice
Example- the code 1276 can be programmed by entering: 5
1276 1276
Factory default setting: 8080
12.45. Go to maintenance mode
By entering 292 while in Service Mode the system switches to
maintenance mode. In maintenance mode it is possible to
program the devices to be bypassed and to adjust the control
panel internal clock (see 13.4).
12.46. Setting the internal clock
The control panel has a built in real-time clock which is used to
time-stamp all recorded events in the control panel memory.
Adjust the clock after installation by entering:
4 hh mm DD MM YY
where:
hh is the time in hours (00 to 23)
mm is the time in minutes (00 to 59)
DD is the day (01 to 31)
a Unsplit system Split system
0 No event No event
1 Set all (ABC) Set all (ABC)
2 Unset all (ABC) * Unset all (ABC)
3 Set A** Set A
4 Set AB** Set B
5 Unset all (ABC) * Unset A
6 Unset all (ABC) * Unset B
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jablotron JA-80K at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jablotron JA-80K in the language / languages: English as an attachment in your email.

The manual is 0,55 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Jablotron JA-80K

Jablotron JA-80K User Manual - English - 1 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info