AS-80 access system control unit MKM51600
1
The AS-80 access system control unit
The AS-80 access control system can operate electric devices such as
door locks, gates or security systems. It consists of two parts - a JA-80H
keypad and/or JA-80N RFID card reader (delivered separately) and the
AS-80 control unit with built-in backup power. One or two keypads can
be wired to each control unit (e.g. they can be installed on both sides of
a single door).
A separate control unit with a built-in backup power supply placed in a
protected (indoor) area insures maximum security.
Communication via the cable from the keypad to the control unit is
encrypted with a sophisticated code protocol. This ensures that there is
no other way to operate the device than by entering a valid access code.
The system can handle 120 user codes and RFID cards. An exit button
can be used for easy door opening from inside.
The keypad itself is made of solid plastic, has a backlight for easy
operation and it is suitable for vandal-proof outdoor applications.
Installation
Installation shall only be undertaken by technicians holding a certificate
issued by an authorized distributor.
Up to 2 keypads / readers (JA-80N/H) can be connected to the AS-80
unit. The first keypad must be set as a master and all programming can
only be done using the master keypad. The second (slave) controller
can be a keypad or an RFID reader.
A keypad or reader can be installed outdoors (IP-65).
1. remove the front panel - unscrew the back-housing screw
2. fix the bottom housing onto the desired place (check that the tamper spring
is properly pushed down).
3. connect the keypad’s cable to the control unit’s AS-80 terminals using
8-wire shielded cable, max. length 150 m
4. put the front panel back and fix it using the screw
5. fix the AS-80 unit onto the desired place
6. connect the cable in the AS-80 unit according to the description below
Note, if you change a master keypad, you must set the system up again!
If a second keypad is used then it should be placed at least 50cm from
the master keypad.
Control unit terminal descriptions:
C1, NC1, NO1 relay switch-over contact, max.1.5 A / 24 V
C2, NC2, NO2 relay switch-over contact, max.1.5 A / 24 V
TMP, TMP NC tamper output, max. 0.1 A / 25 V;
IN, COM Exit button switch input
Connection of the keypad / reader to the AS-80 unit
Keypad wire terminal in the control unit
Red + 12V
Blue GND
Green CLK
Brown DTA
Yellow not connected (used for entering setting mode, it
should be isolated after installation)
Pink not connected
Grey, White TMP
LED indicators on the control unit:
Red 1 ON=output relay 1 is triggered
Red 2 ON=output relay 2 is triggered
Green ON=Power on
LED indicators on the keypad:
Status Open System
Red Green - User mode
Green Green - Service mode
Red Green - The relay is switched on (door is
open)
Red Green - Waiting for confirmation by a
flashing code/RFID card
- - Orange Master and Installer codes are
not programmed
First powering-up
1. Set the keypad’s/reader’s operation mode. The first keypad (or if
only one keypad will be used in the system) must be set as a master. A
second keypad/reader can be added to the system at any time and must
be set as a slave.
To open setting mode:
1. Disconnect the power
2. Disconnect the DTA (Brown) and connect it to the yellow wire
3. Restore the power (the keypad starts continuously sounding)
4. Disconnect the Brown and Yellow wires
To set the JA-80H keypad as a master:
press 0 and when the keypad beeps press 4
To set the keypad / reader as a slave:
If you have a JA-80H keypad, press 0 and when the keypad beeps
press 0 again
1


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jablotron AS-80 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jablotron AS-80 in the language / languages: English as an attachment in your email.

The manual is 0,18 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info