AC-88 smart wireless socket 2/2 MZZ55400
Inverse (switch-off) mode
If an inverse function of the wireless socket is required (e.g.
switching-off the appliances when nobody is at home and the alarm
system is activated), the transmitter can be enrolled in a switch-off
mode:
Enter the 2
nd
enrollment (switch-off) mode,
Send an enrollment signal from the control device according to
description in Switch-on chapter,
The inverse mode should not be used for periodically transmitting impulse
devices
When the signal has been received, it is indicated with a long
flash of the LED indicator on the socket
You can exit enrollment mode by pressing the button on the
wireless socket.
The wireless socket will react inversely. Activation of transmitters
enrolled in the inverse mode switches the socket off, deactivation of
the device switches it on.
Timer use
The timer can only be used with transmitters with pulse reaction (JA-8xP,
JA-8xM) or devices sending panic signals (RC-87, RC-88, RC-89, RC-86).
Activation of an pulse or panic device enrolled to the socket switches the
socket on for preset period of time (factory default is 2 minutes). If it is
requested to change the timer settings, enter the timer setting mode (unplug
the socket from the mains, plug it in again, hold the button until the LED
indicator starts flashing 3 times per second, then release the button). The
first press of the button in the timer setting mode starts counting the desired
switch-on time where one second corresponds to one minute in normal
operation. The counting is indicated by the flashing of the LED indicator on
the socket in 1-second intervals. Another press of the button stops the
counting and exits the timer setting mode. If you want the socket to remain
active for 5 minutes, press the button 5 seconds after the first press in timer
setting mode (indicated with 5 flashes of the LED). The time value is saved
and the wireless socket switches to normal operating mode.
Use with RC-8x remote controls
Up to 8 remote control devices can be enrolled to each socket.
Remote control devices work in the same way as status devices.
However, if they send a panic code, the socket will be switched for preset
period of time.
To control the stair lighting set the timer for the period of time which you
need and then use the RC-88 wireless button in panic mode to control
the socket.
Use with TP-8x thermostats
For convenient controlling of a convector heater the TP-8x thermostat
can be used. Place a thermostat in each room and enroll each one to a
socket for every convector. Plug one convector into each socket.
The thermostat transmits its status every 9 minutes. Therefore
when the power supply is terminated the AC-88 module
returns to the required status within 9 minutes after the
power supply is restored.
A thermostat can be enrolled to a socket in switch-on (heating –
el. boiler control) or switch-off mode (ventilation and air-
conditioning control).
Besides thermostat it is possible to enroll another status
transmitter (e.g. JA-8xM, PG output of the OASIS control panel,
etc) in switch-on mode performing so-called blocking function.
Then if the blocking device is activated (e.g. JA-8xM by an open
window) the socket ignores signals from the thermostat and will
be activated only when the thermostat reports that the
temperature limit has been exceeded (e.g. if there is a danger of
freezing or overheating). If the blocking device such as PG
output should have inverse function (to block the heater while it
is deactivated), then it must be enrolled in the socket in the
switch-off mode.
Use with JA-8x detectors
JA-8xP motion detectors trigger an pulse reaction and therefore they are
enrolled in the switch-on mode to the AC-88 allowing to switch the socket
on for the time set on the timer. The suitable use is for example the
automatic switching of lights, ventilation etc.
JA-8xM detectors can send status (blocking of heating or air conditioning
when the window is open) or pulse signals (switching ventilation, lights,
etc).
Use with OASiS control panel PG outputs
When the control panel’s PGX or PGY output is enrolled in switch-on
mode to the socket, the socket copies its status.
If any of the PG outputs is enrolled in the inverse mode, the socket
remains switched on when the corresponding PG output is switched off
and vice versa.
The socket reacts the same way to signals from control panel PG
outputs as from GD-04 David equipped with GD-04R radio module, and
from EYE-02 GSM security camera (e.g. to switch the external lighting
on during an alarm).
Other devices along with the PG output can be enrolled to the wireless socket.
However, the devices with status reaction except the remote controllers send
repeatedly information about their status every 9 minutes. Therefore enrolling
of 2 status devices periodically transmitting signals to the socket, will result in
an undesirable periodical on/off switching of the socket when one transmitter is
activated and the other one deactivated.. We therefore do not recommend
enrolling 2 and more devices with status reaction and periodical signal
transmission.
The socket as a controller
The socket is also equipped with a built-in transmitter which when the
socket is switched on/off automatically sends on/off signals to another
devices. The button of one socket can thus be used to control other AC-88
sockets or other OASiS system devices (AC-82, UC-82, GD-04R wireless
relays or JA-8xK control panels with JA-82R radio modules). It thus enables
the creation of a chain of sockets and their control from one place (e.g. from
a control panel, a remote control or a master socket). The slave sockets
then react to the commands of the master device. It is thus possible to
switch off the requested appliances (e.g. TV, satellite, video etc.) or switch
the electric heating to an economic mode by activating the house alarm.
The socket transmits its own enrollment signal for other devices when it is
plugged in.
Device RESET
If you need to reset the socket, unplug it from the mains first. Then
plug it in again and hold the button until the LED indicator starts flashing
four times per second then release the button to enter the reset mode.
Then to perform the reset press the button and hold it again until the LED
indicator goes off (approx. 3 seconds).
“Low battery” signalling
If the battery in an enrolled device is low, the LED indicator signals this by
continuous rapid flashing. In such a case replace the battery according to
manual of that device.
Technical specification
Power supply 230V/50Hz, protection class II
Power consumption approx 1W
Relay contact loadability
Resistive load (cosφ=1) max.16A / 250VAC
Inductive (capacitive) load (cosφ=0.4) max.8A / 250VAC
Electrical Outlet Type E
Communication band 868 MHz, OASiS protocol
The devices are enrolled into non-volatile memory and they remain enrolled even
when the power supply is terminated
Maximum number of enrolled devices 8
Minimum transmitter distance 1m
Environment II. indoor general (–10 to +40°C)
Class of protection IP40 according to EN 60529
Mechanical resistance IK08 according to EN 6626
Dimensions: 64 x 91 x 45mm,
Weight:
Comply with ETSI EN 301489-1, 3, EN 61000-6-2, 6-3, EN 60950-1
Conditions for operation ERC REC 70-03
JABLOTRON ALARMS hereby declares that the AC-88 is in compliance
with the essential requirements and other relevant provisions of Directive
1999/5/EC. The original of the conformity assessment can be found at
www.jablotron.com
, Technical Support section
Note: Although this product does not contain any harmful materials we
suggest you return the product to the dealer or directly to the producer after
use.
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jablotron AC-88 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jablotron AC-88 in the language / languages: English as an attachment in your email.

The manual is 0,11 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info