TROUBLESHOOTING (continued)
PROBLEM CAUSE SOLUTION
TUB LOSES AIR
PRESSURE Air valve cap loose.
Air valve base loose.
Hole, cut or split on spa tub.
Ensure air valve cap is securely closed.
Fill up the spa tub with air then make sure the
air valve base is tighten, see “Spa Tub Air Valve
Fastening” section.
Put liquid soap and water in a squirt bottle and
spray on seams. If there is a leak it will bubble.
After you nd the leak, clean and dry the leaking
area, then apply the repair patch that comes with
your spa.
LEAKING BETWEEN
SPA TUB
CONNECTORS AND
CONTROL UNIT
CONNECTORS
Spa control base inlet/outlet
connections not securely tight.
Spa control base inlet/outlet o-ring
missing/dirty.
Tighten inlet and outlet connections.
Coat the o-ring with petroleum jelly for water proof.
Remove grid from inside spa with a screwdriver,
ensure inlet/outlet O-ring is in place, clean and not
damaged.
SPA IS TOO NOISY
IN FILTRATION
MODE ONLY
Control base components not securely
attached.
Control base ground not level and rm.
• Spa lter motor failed.
Ensure control panel, back cover and all inlet/
outlet are securely connected.
Ensure ground is level, rm and smooth.
Replace the failed lter motor with a new one.
INSUFFICIENT
CHLORINE • Insuf cient operating time of the
sanitation system and/or heater is
running at the same time.
Chlorine loss due to intense sunlight
exposure.
The bather load has increased.
Clogged or dirty electrolytic cell.
Increase the sanitation system operating time
and ensure the heater is off during the sanitation
process. See “Sanitation System Operating
Instructions”.
Use a SPA cover when the SPA is not in use and/
or when the sanitation system is operating.
Increase the sanitation system operating time and
test the water using the test strips. See “Sanitation
System Operating Instructions”.
Check and clean the cell if necessary. See
“Maintenance”.
BUBBLE AIR
BLOWER DOES NOT
WORK
Air blower pump is too hot. Turn off and unplug the spa. Let it cool down and
restart all over again.
If problem persists, contact Intex Service Center.
AIR PRESSURE
IS WEAK DURING
INFLATION
Hose adaptor o-ring missing.
• In ation hose adaptor not securely
tighten.
Connection between the hose
adaptor and blower in ation outlet,
and between the in ation hose and
in ation valve are loose.
Air blower failure.
Ensure the o-ring is in place.
Tighten/reinstall hose adaptor.
Finger tighten during in ation.
If problem persists, contact Intex Service Center.
AIR BUBBLES ARE
NOT AS STRONG
AS BEFORE
O-ring missing between the control
base air outlet and spa tub air inlet
connections.
Air connection nut is not securely
tight.
Air bubble channel passage inside the
tub broken or leaking.
Air blower failure.
Ensure the o-ring is in place.
Finger tighten all nuts.
Use repair patch to repair any puncture.
If problem persists, contact Intex Service Center.
IMPORTANT
If you continue to experience dif culty, please contact our Consumer Service Department for
assistance. See separate “Authorized Service Centers” sheet.
31


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Intex PureSpa - 28492 PS-BH-20 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Intex PureSpa - 28492 PS-BH-20 in the language / languages: English as an attachment in your email.

The manual is 5,61 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Intex PureSpa - 28492 PS-BH-20

Intex PureSpa - 28492 PS-BH-20 User Manual - German - 34 pages

Intex PureSpa - 28492 PS-BH-20 User Manual - Dutch - 25 pages

Intex PureSpa - 28492 PS-BH-20 User Manual - French - 34 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info