Performing Additional Functions
To Bypass Zones
The zone bypass menu is used to bypass (isolate) selected
zones in your security system. A bypassed zone is not capable
of activating an alarm, as it is temporarily disabled from your
system.
This option is commonly used to bypass zones that you wish to
temporarily add to your “stay mode”. Whilst still offering
security on the remaining zones, bypassing zones lowers your
level of security. All bypassed zones will reset and unbypass
when your security system is next disarmed. Your security
system must be disarmed (turned off) before being able to
bypass zones. After bypassing the selected zones, your
security system must be armed (turned on in either the away or
stay mode to secure the remaining zones.
1. Enter a valid PIN code to unlock the screen.
2. Touch MENU.
3. Enter a valid PIN followed by ENTER.
4. Touch Security – Zones.
5. Touch the zone number you wish to bypass, if you do not
know the zone number press the List View button to see
the zone names.
6. Touch Bypass.
7. Touch Back to select more zones to bypass.
8. Touch Home to finish.
To Unbypass Zones
1. Enter a valid PIN code to unlock the screen.
2. Touch MENU.
3. Enter a valid PIN followed by ENTER.
4. Touch Security – Zones.
5. Touch the zone number you wish to unbypass. Currently
bypassed zones will be in *blue*. If you do not know the
zone number, press the List View button to see the zone
names.
6. Touch Bypass.
7. Touch Back to select more zones to bypass.
8. Touch Home to finish.
Set up Zone Chime Mode Feature
You can setup your keypad so that it will beep when selected
zones are tripped or activated this is called chime.
Chime mode can be enabled or disabled for each individual
zone and does not trigger any alarms. In this case it is only
used as a low level alert such as a customer entry door.
The zones you have selected to be in the “chime group” are
stored in memory and are not cleared when the security
system is armed and disarmed.
1. Enter a valid PIN code to unlock the screen.
2. Touch MENU.
3. Enter a valid PIN followed by ENTER.
4. Touch Security – Zones.
5. Touch the zone number you want to add to chime mode, if
you do not know the zone number press the List View
button to see the zone names.
6. Touch Chime.
7. Touch Back to select more zones to add to chime mode.
8. Touch Home to finish.
Specifications
Compatibility xGen Security System
Voltage 12.0-13.5 VDC (provided by panel)
Current
170 mA max with sounder and screen on
max brightness,
40 mA in idle mode
Screen Resistive touch 3.5” colour TFT LCD screen
Capacity 512 zones, 96 areas, 644 outputs, 256
users
Wiring xGen 4-wire bus
Code combinations
4 digits
(There are no invalid code combinations.)
10 000
Dimensions (W × H × D) 82 mm x 125 mm x 18 mm
Housing Opal white with silver frame
Weight 125 g
Operating temperature 0° to 49°C
(32° to 120°F)
Storage temperature 34° to 60°C
(30° to 120°F)
Relative humidity up to 90% noncondensing
Regulatory information
Manufacturer Placed on the market by:
UTC Fire & Security Americas Corporation, Inc.
3211 Progress Drive, Lincolnton, NC, 28092, USA
Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
FCC compliance
This equipment has been tested and found to
comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable
protection against harmful interference when the
equipment is operated in a commercial
environment. This equipment generates, uses,
and can radiate radio frequency energy and, if not
installed and used in accordance with the
instruction manual, may cause harmful
interference to radio communications.
You are cautioned that any changes or
modifications not expressly approved by the party
responsible for compliance could void the user's
authority to operate the equipment.
NFPA 72
Check local ordinances, this device is not listed
by an approved test lab to meet NFPA 72 and
therefore may not be sold or installed for use with
a fire system in some localities.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Interlogix NXG-1820-EUR Touch Screen at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Interlogix NXG-1820-EUR Touch Screen in the language / languages: English as an attachment in your email.

The manual is 0,31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info