3. Installation and Operation
3.1 Powering up the Flood Sensor
Remove the battery cover; insert new batteries, noting the
polarity as shown in Fig. 1, and replace the cover. (Requires
2x AAA batteries).
Low battery indication: If the batteries need to be replaced,
the RED LED on the transmitter will ash slowly.
3.2 Installing the Flood Sensor
Mount the transmitter on a xed surface such as a wall using
either double-sided adhesive strips or the screws and wall
plugs provided.
When mounting the water sensor part of the Flood Sensor use
the double-sided adhesive pad. If mounting onto on a porous
surface such as wood or concrete, make sure the surface is
painted to provide proper adhesive bonding.
After installing, test the Flood Sensor using a bowl of water to
be certain it is working properly.
3.3 Installing using Double-Sided Adhesive Pads
• Ensure the mounting surface is clean.
Peel back one layer of the protective lm and attach it to the
transmitter.
Peel back the remaining layer of protective lm and press the
transmitter rmly in place against the mounting surface until
attached.
• Repeat the process to attach the water sensor.
4. House Security Code Settings
Unless the factory settings of the i.onik
®
Alarmsystem Smart
Panel have been altered, the house security code will NOT need
to be changed.
However, if the settings on the Smart Panel have been altered,
or need to be altered to solve the problem of the Smart Panel
and sensors activating intermittently (or not working at all) or
interference with other systems, then the house security code
on all system modules (sensors and sirens)will also need to be
changed.
House Security Code settings can be altered as follows:
• There are 4 jumpers or dip-switches on each device.
Remove the jumper compartment cover, then pull out or plug
the jumper into the contacts to change the House Security
Code.
If a jumper is plugged it is ON if it is removed it is OFF. Default
code is with all the jumpers plugged.
To ensure the system works correctly, make sure the jumpers
on the Smart Panel and all other system modules (sensors and
sirens) match exactly.
Jumpers for
house
security code
- Smart Panel
- Each sensor
Default house code:
1: ON, 2: ON, 3: ON, 4: ON
*Jumper:
ON = Plugged,
OFF = Pull Out
Dip-Switches
for house
security code
- Key Fob Remote
Default house code:
1: ON, 2: ON, 3: ON, 4: ON
5. Zone Code Settings
The sensor is supplied with a pre-assigned zone setting.
The sensor can be assigned to a different zone as follows:
Unscrew and remove the jumper compartment cover on the
rear of the sensor.
In the area marked “Zone Code” there are eight pairs of
metal contacts with a number next to each.
The number corresponding to the pair of contacts which is
plugged with a jumper is the current zone.
To re-assign to a different zone simply unplug the jumper
from its current zone and plug it across the contacts corres-
ponding to the new zone number selected.
Jumpers for
zone code
Default zone code: Zone 1
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for I-onik WS-106 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of I-onik WS-106 in the language / languages: English, German as an attachment in your email.

The manual is 0,33 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info