625723
5
Zoom out
Zoom in
Previous page
1/23
Next page
5
DESCRIPTION OF THE CHARGER (FIG I, PAGE 2)
The chargers CT 160 and CT 210 are designed to charge lead acid batteries with liquid electrolyte,
nominal voltage from 12V, and with capacity according to the table II, page 2.
1 – Ammeter 5 – Fuse
2 – Battery voltage selector 6 – cables + clamps
3 – Battery capacity selector 7 – handle (CT 210 only)
4 – Main switch 8 – Power supply (CT160 : fixed / CT210 : removable)
CHARGER MODE
Preliminary precautions
For indoor use, with good ventilation. Protect the charger from rain and moisture.
Remove the battery caps if there is, and check the level of liquid. If it is not correct, filled up with
distilled water. Clean well the battery terminals.
Check if the battery capacity and voltage are compatible with your charger. Do not charge the
battery when it is connected on the vehicle
Connection and disconnection
Connect the clamps (+ red, - black) to + and - battery terminals, making sure you get a good electric
contact, respecting the following order:
Connect first the battery terminal not connected to the chassis of the vehicle.
Then connect the other connection to the chassis remote from the battery and any fuel line.
At last, plug in your charger to 230 V 50/60 Hz mains supply.
Choose the charge voltage (12 / 24V) and the charge speed (normal or boost). The « Boost »
function allows charging a battery quickly.
Control and end of the charge process
These are traditional chargers; the charge process must be stopped manually.
The ammeter is a charge indicator. When the current drops down to 0, the battery charge is ending.
You can stop the charge process. In normal mode, it takes about 10 hrs to fully charge a battery. If
the ammeter is not at the minimum after this period, check the charge mode and voltage or have the
battery checked by a professional.
Do not let the charger connected more than 24 Hours on a battery.
After charging, disconnect the battery charger from main supply. Then remove the chassis connection
and the battery connection, in this order.
PROTECTIONS
Your product has been developed with a maximum of protections.
The clamps of the battery are isolated.
The polarity reversal will not cause danger. The protection is insured by an automotive fuse, which
must be changed in case of polarity error. Respect the rating of the fuse, which is indicated on the
charger.
This device is protected by an internal fuse to avoid any risk in case of damage to the charger.
(CT160 : 1,6A – CT210 : 2A)
Thermal protection: the transformer of the product is protected by a thermal switch. If the charger is
used intensively, it may switch in thermal protection mode (cooling time about 15min), and then
resume the charge.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gys CT160 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gys CT160 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 0,93 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info