20
GTB 16/5R | GTB 16/12RL
GB
ENGLISH
Read and understand the
operating instructions before
using the appliance. Familiarise
with the control elements and how to use the
appliance properly. Abide by all the safety measures
stated in the service manual. Act responsibly toward
third parties. The operator is responsible for accidents
or risks to third parties.
In case of any doubts about connection and operati-
on refer please to our customer center
Speci ed Conditions Of Use
Bench drills must not be used for metal cutting,
machining of wood and plastics; Respecting technical
data and safety precautions.
The machine may only be operated by one
person. Make sure there is nobody present in the
dangerous area. The minimum distance is 2 m.
Operation is only allowed with a safety switch
against stray current (RCD max. stray current of
30mA).
The machine cannot be used for works other than for
which the machine has been designed and that are
speci ed in the Operating Instructions. Any other use
is a use in con ict with the designation. The manufac-
turer will not be liable for any consequential damage
and injuries. Please be sure to know that the machine
has not been designed for industrial purposes.
Technical Data
Bench drill ..............................................................GTB 16/5R .............................................................. GTB 16/12RL
Art. No ................................................................................................55190 .......................................................................................55192
Voltage ~ frequency .............................................230 V~50 Hz .......................................................................... 400 V~50 Hz
Motor output ............................................... 600 W / P1 S6 60% ..............................................................600 W / P1 S6 60%
IP 44
Protection type ...................................................................... IP 44 ......................................................................................... IP 44
Quill stroke .......................................................................... 60 mm .....................................................................................60 mm
Chuck ............................................................................... 3 - 16 mm ...............................................................................3 - 16 mm
Reach ...................................................................................120 mm .................................................................................. 125 mm
Bench size ..............................................................192 x 192 mm .......................................................................192 x 192 mm
Base plate size ......................................................340 x 205 mm .......................................................................340 x 205 mm
5 Stufen
Quill speed .........................................5 steps 450 - 2500 min
-1
................................................. 12 steps 230 - 2470 min
-1
Fixture ...........................................................................MK 2 - B 16 .............................................................................MK 2 - B 16
Weight. ..................................................................................... 30 kg ........................................................................................30 kg
Noise and Vibration Information
Sound power level L
WA
1)
............................................... 80 dB (A) .................................................................................80 dB (A)
Wear ear protectors!
General instructions for electric
tools
WARNING
Read all safety instructions and manuals. Failure to
follow the safety instructions and manuals may result
in electric shock,  re and/or serious injuries.
Save all warnings and instructions for future
reference.
The term „electric tools“ used in the safety instruc-
tions refers to electricity-powered tools (including
electric cable) and battery-powered tools (without
electric cable).
1) Safety in the place of work
a) Keep the place of your work clean and well lit.
Mess or an unlit workplace may lead to injuries.
b) Do not work with electric tools in conditions with
ammable liquids, gases or dust. Electric tools
produce sparks able to ignite dust or fumes.
c) Keep children and other persons outside the
place where the electric tools are used. When
not concentrated, you may lose control over the
machine.
2) Electrical safety
a) The plug of an electric tool must strictly
correspond to the socket. The plug must not
be altered in any case. Do not use any adapters
together with earthed electric tools. Unaltered
plugs and appropriate sockets reduce the risk of
electric shock.
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gude GTB 16-5 R - 55190 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gude GTB 16-5 R - 55190 in the language / languages: English, German, Dutch, French, Italian as an attachment in your email.

The manual is 12,67 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info