590776
31
Zoom out
Zoom in
Previous page
1/96
Next page
GMC-I Messtechnik GmbH 31
10.1 Earthing Resistance Measurement – Mains Operated
The following types of measurement or connection are possible:
2-pole measurement via 2-pole adapter
2-pole measurement via earthing contact plug
(not possible in IT systems)
3-pole measurement via 2-pole adapter and
probe
Selective measurement: 2-pole measurement
with probe and current clamp sensor
At left in figure:
2-pole measuring
adapter for con-
tacting PE and L
measuring points
At right in figure:
The PRO-Schuko
measuring
adapter can be
used as an alter-
native.
Select Measuring Function
Select Operating Mode
The selected operating mode is displayed inversely:
mains~ in white against a black background.
Battery powered measurement is not possible:
The error message shown at the left appears
if the selected connection type is inappropri-
ate for the operating mode.
Special Case: Manual Measuring Range Selection (test current
selection)
(R AUTO, R = 10 k (4 mA), 1 k (40 mA), 100 (0.4 A),
10 (3.7 ... 7 A), 10 /U
E
)
Note
When the measuring range is selected manually, accuracy val-
ues are only valid starting at 5% of the upper limit range value
(except for the
10
range; separate display for small values).
Set Parameters
q Measuring range: AUTO, 10 k (4 mA), 1 k (40 mA), 100
(0.4 A), 10 (> 3.7 A)
In systems with RCCBs, resistance or test current must be se-
lected such that it is less than tripping current (½ I
N
).
q Contact voltage: UL < 25 V, < 50 V, < 65 V, see section 5.7 re-
garding freely selectable voltage.
q Transformer ratio: depends on utilized current clamp sensor
q Connection type: 2-pole adapter, 2-pole adapter + probe,
2-pole adapter + clamp meter
q Type of system: TN or TT
q Test current waveform
See section 10.4 through section 10.6 regarding advisable parame-
ters for the respective measurement and connection types.
Perform Measurements
See section 10.4 through section 10.6.
10.2 Earthing Resistance Measurement – Battery Powered
(only MPRO & MXTRA)
The 5 following types of measurement or connection are possible:
3-Pole measurement via PRO-RE adapter
4-Pole measurement via PRO-RE adapter
Selective measurement with clamp meter
(4-pole) via PRO-RE adapter
2-clamp measurement via PRO-RE/2 adapter
Measurement of soil resistivity
E
via PRO-RE adapter
Figure at right:
PRO-RE adapter for connect-
ing earth electrode, auxiliary
earth electrode, probe and
auxiliary probe to the test
instrument for
3/4-pole measurement,
selective measurement and
measurement of soil resistivity
Figure at right:
PRO-RE/2 measuring adapter as
accessory for connecting the E-
Clip 2 generator clamp for 2-clamp
measurement and earth loop resis-
tance measurement.
Select Measuring Function
Select Operating Mode
The selected operating mode is displayed inversely:
white battery icon against black background.
Mains powered measurement is not possible:
The error message shown at the left appears
if the selected connection type is inappropri-
ate for the operating mode.
Set Parameters
q Measuring range: AUTO, 50 k, 20 k, 2 k, 200 , 20
q Current clamp sensor transformer ratio:
1:1 (1 V/A,) 1:10 (100 mV/A), 1:100 (10 mV/A), 1:1000 (1 mV/A)
q Connection type: 3-pole, 4-pole, selective, 2-clamp,
E
(Rho)
q Distance d (for measuring
E
): xx m
See section 10.7 through section 10.11 regarding advisable
parameters for the respective measurement and connection
types.
Perform Measurements
See section 10.7 through section 10.11.
R
E
R
E
31

Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt PROFITEST MPRO at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt PROFITEST MPRO in the language / languages: English as an attachment in your email.

The manual is 2,28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gossen Metrawatt PROFITEST MPRO

Gossen Metrawatt PROFITEST MPRO User Manual - Dutch - 92 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info