776259
2
Zoom out
Zoom in
Previous page
1/62
Next page
2GMC-I Messtechnik GmbH
LCD Panel
Setup Menu
Rotary
Selector Switch
Guide for
Carrying Strap
Guide for
Carrying Strap
MEM:Key for
memory functions
ESC: Return from
submenu /
Activate instrument
from standby state
Control Panel
Fixed Function Keys
MAINS/NETZ LED
see below
IΔN:Triggering key /
compensation (offset)
HELP: Access context
sensitive help
START:Switch on /
start measurement
Softkeys
Parameter selection
Limit value specification
Entry functions
Memory functions
LED Indications (see also section 16)
LED Case A LED Case B
LCD Case A LCD Case B
Function – Cause
A Lights up green: Correct connection, measurement enabled
B Blinks green: Neutral conductor not connected, measurement enabled
A
Lights up orange:
2 different phases active (no neutral conductor at mains), meas. enabled
B Blinks red: IΔN, IF, ZL-PE, ZL-N, RE: No line voltage or PE interrupted
C Lights up red:RINS and RLO: Interference voltage detected, measurement disabled
UIΔ, UIΔN:
Touch voltage > 25 or 50 V, measurement disabled: display: U.PE > UL!
IΔN: During the tripping test with IN, the RCD is not tripped within 400 ms
(1000 ms for selective RCCBs of type RCD S).
IF : With rising residual current, the RCD is not tripped before reaching IN.
After safety shutdown
RLO
:
The permissible (selected) limit value has been exceeded.
RINS, RE(INS)
:
The permissible (selected) limit value has been exceeded.
Mains
Green
Mains
Blinks green
N
PE
L
N
PE
L
x
Mains
Orange
Mains
Blinks red
N
PE
L
N
PE
L
N
PE
L
x
LIMIT
Red
Limit LED
see below
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt Profitest Intro at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt Profitest Intro in the language / languages: English as an attachment in your email.

The manual is 1.69 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info