606987
4
Zoom out
Zoom in
Previous page
1/11
Next page
5
Power supply
The power supply of the radio motor valve drive is provided by two
alkaline batteries (type: Mignon, AA, LR6, 1.5 V, 2,600 mAh).
Insert battery
1. Unlock the lower cover with the included special
key and fold open the cover.
2. Insert the two batteries in the cover. Ensure
proper poling when doing so.
3. Quickly close the lower cover of the radio motor
valve drive and lock it with the special tool.
All LEDs light up briefly.
Then the calibration traverse begins
automatically.
If the radio motor valve drive has not been taught
in, it moves into the emergency position following
the calibration traverse (valve opening 30 %).
If the radio motor valve drive has been taught in,
the heating is adjusted to the specified setpoint
temperature.
Behaviour with decreasing battery voltage
If the battery voltage drops below a defined value, the middle LED flashes
every 10 minutes or after one of the two buttons is pressed (flashing
signal 5 times in 15 seconds). In this state you should replace both
batteries.
Following the manual display of the "Battery drained signal" after
pressing one of the buttons, the automatic display of the "Battery drained
signal" is suppressed for 24 hours.
If operation (e.g. for setpoint offset) is carried out in the "Battery drained"
state, first the flashing signal must be waited for, before further operation
via the buttons is possible.
If the battery voltage drops so far that no temperature control is possible,
the radio motor valve drive moves into the emergency position (valve
opening 30 %). This state is indicated by continuous flashing of the
middle LED at an interval of 3 seconds.
Ensure proper battery poling!
When inserting the batteries, observe the poling marking in the cover.
False polarity of the power supply due to incorrectly inserted batteries
can lead to a device defect.
Use only alkaline batteries (type: Mignon, AA, LR6, 1.5 V). Never use
rechargeable batteries, as they have a steeper discharging curve than
conventional batteries.
+
+
i
Malfunction after changing batteries
If the battery compartment is closed too slowly, the supply voltage may
be switched on and off briefly. This can trigger a malfunction of the radio
motor valve drive. In this case, open the battery compartment for approx.
1 minute and then close it quickly in one motion.
i
Radio connection is retained
The taught-in radio connection is retained, even when the batteries are
changed.
Batteries
Dangers and disposal information
Keep batteries out of reach of children.
Immediate remove used batteries and dispose of them in an
environmentally friendly manner.
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gira 118700 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gira 118700 in the language / languages: English as an attachment in your email.

The manual is 0,11 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gira 118700

Gira 118700 User Manual - German - 11 pages

Gira 118700 User Manual - Dutch - 12 pages

Gira 118700 User Manual - French - 10 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info