Ferm 57
Check that the power rating on your appliance cor-
responds with the power rating at you mains supply.
The supply voltage must be 230 - 240V.
Never run this appliance dry - out of the water. If the
appliance overheats, the thermal cut-out will switch
it off. If this happens wait 5 minutes before using the
appliance again.
Always have the appliance switched off and the plug
removed from the power socket before placing it in
or removing it from the water. Only switch the
power back on with dry hands.
Never use this appliance in a pond or swimming pool
while people are present - in the water!
Electrical Information (only for the UK)
The wires of this appliance are coloured in accordance
with the following code:
Brown: Live (L) or Red
Blue: Neutral (N) or Black
Green and Yellow or Green: Earth (E) (symbol here).
This appliance must be earthed.
3 pin plugs must comply to BS1363
Fuse must be 5 amp and comply to BS1362
If the plug needs replacing, the new plug must be wired in
accordance with the following instructions:
Connect the Blue wire to the terminal marked NEU-
TRAL (N). Connect the Brown wire to the terminal mar-
ked LIVE (L). Connect the Green and Yellow wire to the
terminal marked EARTH (E) (symbol here).
!IF IN DOUBT CONSULT A
QUALIFIED ELECTRICIAN!
All electrical connections e.g. extension cable, must be of
an approved waterproof type for outdoor use. Exten-
sion cables must be three-core, one of which is EARTH.
Always fully unwind extension cables before use.
Connection to the mains power supply must be via an
approved residual current device (RCD), with a residual
operating current not exceeding 30mA.
3. GENERAL USE
This pump is NOT designed for continuous opera-
tion e.g. as a swimming pool or pond circulation
pump.
If used as an intermittent pump to circulate water in
an ornamental pond, it must be sited in a sump or
behind a suitable barrier to stop pond life being suc-
ked into it.
Use a rope to lower the pump into deep water -
never lower the pump by its power cord or delivery
pipe at any time.
Ensure there are no obstructions around the inlet
openings around the base of the pump. The inlet ope-
nings must be clear of mud or sludge at the bottom of
a pool.
It would be advisable to stand the pump of a solid plat-
form at the bottom of the pool to keep it upright, if
practical to do so.
If the pump is used to drain a swimming pool it must
only be used when the pool is completely empty of
people.
It is important that the floating switch is allowed to
reach its ON height in the water. It must also be able
to float down without obstruction in order for it to
switch off when required.
After use allow the pump to run using clean water for
2 - 3 minutes in order to remove residues and parti-
cles that may have accumulated in the pump and out-
let hose.
NOTE:
If the level of water becomes to low, any sludge in the
shaft will dry out more quickly and this may prevent the
pump from restarting. To ensure the pump works effi-
ciently the bottom of the shaft must be kept free of sludge
as far as possible and cleaned on a regular basis when not
in use.
MAINTENANCE
There are no user serviceable parts in this appliance. If
the appliance appears to be blocked, switch off the
power at the mains, remove the plug from the socket and
check the appliance for blockages (see 'Blockages').
BLOCKAGES
If you suspect the pump has become blocked, switch off
the power at the mains socket remove the plug and exa-
mine the turbine. The turbine can be accessed by remo-
ving the securing screws in the base and/or sub base.
Alternately try reaching the suspected blockage through
the outlet pipe in the side of the pump.
Always flush through with clean water after every
use.
IMPORTANT: During maintenance or cleaning never
rest the appliance of the on the turbine (impeller).
4 Ferm
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ferm CPM1004 - FSCWP 1000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ferm CPM1004 - FSCWP 1000 in the language / languages: All languages as an attachment in your email.

The manual is 3,45 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info