632755
3
Zoom out
Zoom in
Previous page
1/30
Next page
58 Ferm
PARTS LIST FSCWP-1000
REF. NR. DESCRIPTION PC
6 FLOAT SWITCH 501356
34 + 47 TILL 49 VANA COMPLETE 501372
50 TURBINE HOUSING 501373
51 MESH COVER 501374
CLEAN WATER PUMP
SAFETY AND OPERATING INSTRUCTIONS
For your own safety and for the safety of others,
please read these instructions carefully before
using this appliance. Keep in a safe place for future
reference.
CONTENTS
1. Technical specifications
2. Safety instructions
3. General use
4. Operating instructions
5. Trouble shooting guide
1. TECHNICAL SPECIFICATIONS
CONTENTS OF PACKING
1 Pump
1 Universal connector
1 Instruction manual
1 Guarantee card.
1 Safety instructions
FEATURES
1. Carry handle
2. Float ON/OFF switch
3. Base
4. Main motor housing
5. Universal connector
6. Power cable
2. SAFETY INSTRUCTIONS
EXPLANATION OF SYMBOLS
In accordance with essential applicable safety
standards of European directives
Risk of damaging material and/ or physical injuries.
Min head
Max depth
Faulty and/or discarded electrical or electronic
apparatus have to be collected at the appropriate
recycling locations
Dispose of plastic bags safely - they are a suffocation
hazard for young children.
Please read these instructions carefully and tho-
roughly before using this appliance and keep them for
future reference. It is very important that you under-
stand how to use this appliance safely so please take
the time to familiarise yourself with the requirements
as outlined in these instructions.
If you are in any doubt what so ever about using this
appliance, we strongly recommend that you employ
the services of a suitably qualified person.
Electrical connection must be protected by a residual
current device (RCD) at the power socket with a
nominal trip current of 30mA (max).
Keep children and pets well away from the work area
and never allow children to use this appliance or
touch the extension cord at any time. When not in
use, keep this appliance stored in a safe place out of
reach of children.
Never leave the appliance unattended when in use.
Never pull the appliance by its power cord. Carry it
using the carry handle.
Do not allow the power cord to lay on or across
sharp objects that might pierce the outer insulation.
Carry out a visual inspection of the power cord
before use and if it is damaged, have it replaced by a
specialist service centre. Do not use the appliance if
the cord is damaged.
Keep the power cord away from heat, frost, oil, sol-
vents or any sharp objects or edges.
Electrical connections e.g. extension cable, must be
protected from moisture at all times.
Model | FSCWP-1000
Float Switch | YES
Application | Clean water
Voltage | 230 - 240 V 50 Hz
Input power | 1000 W
Max Pumping Capacity | 18.000 l/h
Max Pumping Height | 16 m
Max Depth for unit | 5 m
Max. Particle size | dia. 4mm
Hose Connection | 1 1/2" threaded connector
Power Cable length | 10 m
Maximum water temp. | 35 °C
Weight | 10 kg
Ferm 3
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ferm CPM1004 - FSCWP 1000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ferm CPM1004 - FSCWP 1000 in the language / languages: All languages as an attachment in your email.

The manual is 3,45 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info