In addition there is the facility to connect 4 hard wired zones to the Control
Panel, each of which is fully configurable with the same features as the wirefree
zones (1-32).
ENTRY/EXIT DELAY
When the system is armed with the Exit-Delay enabled, no alarm signal from
any detector on an active zone will be able to initiate an alarm until the Exit-
Delay has expired. This enables the system to be armed from within the
property and allows time for the user to exit the property without triggering an
alarm. If the Exit-Delay is disabled then detectors on active zones will
immediately be able to initiate an alarm as soon as the system begins to arm.
The system Exit-Delay may be configured for between 10 to 250 seconds or
disabled completely.
If a detector on a zone with its Entry-Delay enabled is triggered, then an alarm
condition will not occur until the Entry-Delay period has expired. This allows time
for the user to re-enter the property and disarm the system before an alarm
condition occurs. Generally only the zones on the main entry route to the
property will be configured with an Entry-Delay. The remaining zones would be
configured with their Entry-Delay disabled allowing them to immediately initiate
an alarm a detector on the zone is triggered.
The Entry-Delay for each zone may be configured for between 10 to 250
seconds or disabled completely.
QUICK SET
The system may be fully armed in 5 seconds using the quick set facility,
overriding the programmed exit-delay.
This is useful for setting the system at night when the exit-delay warning beep
will be silenced after just a few seconds.
ZONE LOCKOUT
If a detector on an active zone is triggered while the system is armed an alarm
condition will occur. After the programmed alarm duration has expired the alarm
will stop. If a single zone initiates an alarm
condition more than three times then that zone will be ‘Locked Out’ and any
further alarm signals from that zone will be ignored until the system is
disarmed.
Note: The ‘Zone Lockout’ feature can be disabled if required.
EVENT LOG
The Control Panel incorporates a memory capable of storing the last 50 system
events. This enables the user to see which user has Armed/Disarmed the system
and if and when any alarms occurred. The time, date and details of the event
type will be recorded for each system event.
BATTERIES
Before removing the battery cover on any device to replace the battery, ensure
that the system is put into Test mode to avoid initiating an Alarm.
The specifications for replacement batteries are as follows:
Note: Rechargeable batteries should NOT be fitted.
At the end of their useful life the batteries should be disposed of via a suitable
Recycling Centre. Do not dispose of with your normal household waste. DO
NOT BURN.
The Rechargeable batteries contain Sulphuric Acid – DO NOT ATTEMPT TO OPEN
THE CASING.
ENEN
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elro HA68 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elro HA68 in the language / languages: English as an attachment in your email.

The manual is 3,7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Elro HA68

Elro HA68 Quick start guide - English - 1 pages

Elro HA68 Quick start guide - German - 1 pages

Elro HA68 User Manual - German - 34 pages

Elro HA68 Quick start guide - Dutch - 1 pages

Elro HA68 User Manual - Dutch - 34 pages

Elro HA68 Quick start guide - French - 1 pages

Elro HA68 User Manual - French - 34 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info