EL-2601 Wireless magnetic contact Funkmagnetkontakt Contact magnétique Magneet contact Conrad No: 1276474
enters Test mode during which a transmission is sent every few seconds. You
can terminate Test mode by closing the Tamper switch.
Note: Due to the occurrence of voltage delay in lithium batteries that
have been in storage, the batteries may initially appear to be dead. In
this case, leave the unit in Test mode for a few minutes until the battery
voltage level is stabilized.
When handling the PCB, do not apply pressure on the antenna.
3. From the Programming menu, select Devices, Zones [911].
4. Select the zone to which you want to register the transmitter; the system
initiates Registration mode.When Save? appears on the panel’s LCD display,
press „Yes“.
5. After registration, press the EL-2601’s tamper switch to terminate Test mode.
6. Before permanently mounting the unit, test the transmitter from the
exact mounting position.
7. To remove the PCB, press the PCB release tab and carefully lift the board and slide the board away from the back cover.
8. The EL-2601 is able to operate in three modes: Magnetic Switch, Universal Transmitter or a combination of the two. If
connecting a wired contact loop (N.C.), connect the terminal block as follows: 1 - Alarm; 2 - GND. For this purpose, a wiring
knockout is provided in the back cover.
9. Mount the back cover using two screws and replace the PCB. Use ISO 7050 (ST3.5 x 22) or similar countersunk
screws so that the screw head will not touch the PCB see Figure B.4.
10. To open the magnet’s housing, insert a small screwdriver into one of the pryoff slots located at either end of the magnet’s
back cover and lift to separate from the front cover.
11. Mount the back cover of the magnet using two screws. Make sure that the
guideline on the magnet is correctly aligned with the guideline on the transmitter. Do not install the magnet further than 1cm from
the transmitter.
12. Test the transmitter, making certain that the LED is lit when opening the door/window and again when closing.
13. Close the front covers of the transmitter and the magnet.
TECHNICAL DATA
Antenna: Built-in Whip
Frequency: 868.35MHz FM
Power: 3.6V ½ AA Lithium Battery
Current Consumption: 25mA (transmission)
10μA (standby)
Loop Input Voltage Range: 0-15VDC/AC (peak to peak)
RFI Immunity: 40V/m
Operating Temperature: 0 to 60°C
Dimensions: 65 x 30 x 25mm
France
CONTACT MAGNÉTIQUE
Le EL 2601 est un contact magnétique conçu pour une installation sur des portes
et des fenêtres. Ce produit fait partie de la série Electronics Line Secuplace et
fonctionne avec le système d’alarme Secuplace. Pour en
savoir davantage sur le système complet, les possibilités et le
réglage de la série Secuplace,voyez les instructions d’installation
sur notre site www.electronic-lines.com
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Electronics Line EL-2601 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Electronics Line EL-2601 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 0,48 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info