Introduction
The 801 Modulator offers manual control and digital temperature adjustment of
your Airtronic heater.
Switching on the Heater (Manually)
Press the key and ‘ON’ will briefly appear on the display. The heater will
commence its start up cycle.
Also, the green LED ‘Heater ON’ indication light will illuminate and the display
will now revert to show ambient temperature (°C).
Note: The 801 10 001 version will only run for a maximum period of 1 hour.
The ambient display temperature range is from -9°C to +59°C.
Switching off the Heater (Manually)
The heater may be switched off at any time by pressing the key.
The heater cooling down cycle of 3 minutes will then be initiated. Wait for
blower fan to stop before isolating batteries (if isolator is fitted).
Adjusting the Temperature
Pressing the or keys will alter the desired temperature shown on
the display. This level may be adjusted at any time and will remain in the
modulator memory when the heater is not in operation.
When the or keys are released the display will revert back to show
ambient temperature.
The Modulator temperature adjustment range is from 5°C to 32°C.
Part Number: 801 10 001
Modulator with Diagnostic Readout Instructions (1 hour run)
Part Number: 801 10 003
Modulator with Diagnostic Readout Instructions
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eberspacher Digital Modulator 801 Series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eberspacher Digital Modulator 801 Series in the language / languages: English as an attachment in your email.

The manual is 0,53 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info