ATTENTION
The maximum pressure
produced by the pump must
be at least 1-1.5 bar higher
than the start-up pressure
( Pm ) . If the pressure
produced by the pump is too
low, PRESFLO
®
will stop the
pump and indicate a ‘dry
running’ error message.
When disposing of any PRESFLO
®
parts, adhere to the
relevant laws and regulations in force in the country in
which the equipment is being used. Do not dispose of
any polluting parts in the environment.
ATTENTION
The pressure applied by the
water column above
PRESFLO
®
must not exceed
that of the pump start-up
pressure ( Pm ).
If, for example, PRESFLO
®
is
installed at a height 20
metres below that of the
highest tap in the system, the
pressure detected by
PRESFLO
®
will be
approximately 2 bar.
A model with Pm = 2.2 bar
should, therefore, be installed
in order to guarantee that the
pump is started when a tap
is turned on.
max
= 22 m
Red
Blue
Yellow
= 15 m
= 8 m
Electrical connections
ATTENTION
The cable bushings and circuit
board cover must be properly
assembled and secured in order
to guarantee IP 65 grade protection
of the electrical components.
First start-up
Priming the pump
For instructions on how to prime (fill) the pump, see the pump
manual.
ATTENTION
PRESFLO
®
is fitted with a check valve: do not use the PRESFLO
®
’s
outlet to fill the pump for priming.
Switching the pump on
The red (Power) LED lights up; PRESFLO
®
instantly
detects that there is no pressure within the system
and starts the pump (the green ‘Status’ LED lights up).
If, within 15 seconds of starting up, PRESFLO
®
does
not detect the correct priming of the pump, it stops
the pump and indicates a ‘dry running’ error message.
ATTENTION
When the pump is started for
the first time, it may have to be
run for longer in order to
complete the priming procedure. Press the START/STOP
button to restart the pump and
complete the priming procedure.
STATEMENT OF COMPLIANCE
Under our exclusive responsibility, we hereby declare that this
product is compliant with the following EU Directive and relevant
implementing national regulations:
73/23/CEE, 89/336/CEE, EN 60730-2-6, EN 61000-6-3
Bigarello 24.05.08 DGFLOW S.r.l.
Director
Stefano Concini
CODE:
V / Hz:
I max:
P start:
Year:
V00101101
230 / 50 - 60
16 A
1.5 Bar
2008
Product code
number
ATTENTION: when ordering spare parts, always state the
position n
°
from the diagram below and the product code number
found in the pressure-flow regulator technical data table.
Exploded view of spare parts
Disposal
The electrical connections should
be made as indicated in the
diagram which can also be found
on the inside of the circuit cover.
SEAL
CABLE BUSHING
1 - Circuit board cover
2 - Pressure gauge
3 - Circuit board
4 - Cable bushings
5 - Valve unit
Size
MOTOR
LINE
NUT
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for DGFlow Presflo at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of DGFlow Presflo in the language / languages: English, French, Italian, Spanish as an attachment in your email.

The manual is 0.38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info