Fig. 15
Fig. 13
110 mm
minimum from
nearest
obstruction
60 mm
fixing
centres
Fig. 14
t
s
INSTALLATION INSTRUCTIONS
NEW INSTALLATION
Choose a fixing position where the TP5E will sense the
room temperature without being affected by draughts or
heat sources such as radiators, open fires of direct
sunlight, see fig. 13. Fix at a height of approximately 1·5
metres from the floor. Cable entry is from behind if fitted
to a single gang flush box; or from above, below or from
the left if surface fixed cabling is used. Fig. 14 shows the
fixing hole dimensions and the clearance required for
removal of the sliding battery cover. Standard M3·5
screws are used to fix the TP5E to a flush box, or No.6
woodscrews and wallplugs of adequate length should be
used for surface fixing.
REPLACING AN ORDINARY ROOM THERMOSTAT
Switch OFF the power supply to the heating system.
Carefully note which wire colours are connected to which
terminal numbers of the existing thermostat, and note the
function of each terminal. If the existing thermostat has
no indication of the function of each of its terminals, then
a qualified electrician should be called before proceeding
further.
Remove the existing thermostats mounting plate from
the wall, if applicable, and prepare the wall to receive the
TP5E. Refer to fig. 14 for dimensions. Connect the wires
to the TP5E as shown in fig. 15.
If the existing wires are too short to connect to the TP5E
then a pattress (PT05) should be fixed to the wall and
used to terminate the existing wiring. New wires can then
be extended from the pattress to the TP5E, which can
then be fixed to the pattress with the screws provided.
NOTE. Some existing thermostats will have a Neutral
wire and/or an Earth wire connected. These are not
required by the TP5E and must not be connected to any
TP5E terminals, but should be made electrically safe and
coiled in the recess at the back of the TP5E. If in doubt
about the function of any existing wire, call a qualified
electrician for advice.
Selecting the control mode
The TP5E can operate either in on/off control mode or
in chrono-proportional control mode. This is selected
by means of a small link on the rear of the product
(see fig.15 for location)
The unit is factory set to on/off control with the link in
place. When in on/off mode the thermostat cycles the
heating on and off within its switching differential. If
chrono-proportional control is selected the thermostat
learns and attempts to reduce the switching differential
thus improving comfort.
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Danfoss TP5E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Danfoss TP5E in the language / languages: English as an attachment in your email.

The manual is 0,3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Danfoss TP5E

Danfoss TP5E User Manual - Dutch - 2 pages

Danfoss TP5E User Manual - French - 1 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info