NOTE
While in programming mode (but not in time setting), if no
buttons are pressed for 2 to 3 minutes the TP5E
automatically returns to RUN mode, and the programme
set up to that moment will be active. This programme may
not be the one intended so review the settings again,
before returning to RUN by pressing PROG at setting 6,
days 6 & 7.
EVERYDAY OPERATION
When all twelve time/temperature
settings have been checked and/or
altered, ensure the TP5E is in the RUN
mode, with the colon blinking, (see fig.
7), before sliding the cover shut.
TIME OR TEMPERATURE DISPLAY
The TP5E will always display the time
and required temperature after a
RESET. Once the switching times and
temperatures have been set and the
unit returned to the RUN mode, the
actual room temperature can be displayed instead of the
time. To change between time and temperature display
press the + and - buttons together. Fig. 8 is a typical
temperature display showing the actual temperature, the
required temperature, and flame and thermometer
symbols. The flame symbol appears in either time or
temperature displays when the TP5E is calling for heat.
MANUAL OVER-RIDE
The programmed control temperature
may be changed temporarily using the
s and t buttons until the required
temperature is shown. An s or t
arrow will appear in the display as a
reminder that the programmed setting has been over-
ridden, (see fig. 8 again). This over-ride is cancelled at
the next programmed switching.
WEEKEND into WEEKDAY OVER-RIDE
To use days 6 & 7 settings during any of days 1 to 5 press
the s and t buttons together, (see fig. 9). This over-ride
is cancelled by selecting Constant Temperature Control
(see below) or when the time reaches 2:00.
CONSTANT TEMPERATURE OVER-RIDE
To set the TP5E to control at a constant temperature of
5°C press the s and t buttons together, once from
Weekend/Weekday over-ride or twice from RUN mode.
The required constant temperature
may now be set using the s and t
buttons, and can be anywhere in the
range 5°C to 30°C. At 5°C a snowflake
symbol appears in the display (see fig.
10) indicating frost protection mode*;
at all other temperatures an s arrow
appears (see fig. 11) indicating a
constant temperature selection. This
over-ride is cancelled by pressing the
s and t buttons together.
*NOTE
The TP5E will only provide frost protection to the area in
which it is fitted. It WILL NOT provide frost protection in
unheated areas, and may not provide frost protection in
heated areas not controlled directly by the TP5E.
BATTERY REPLACEMENT
When the batteries approach the end
of their life, a battery symbol blinks in
the display (see fig. 12). When this
symbol appears both batteries should
be replaced with high quality alkaline
cells. 15 days after the symbol appears the TP5E will
switch off. While the battery symbol is blinking the batteries
may be changed without loss of time or programme.
Have the new batteries unwrapped and ready, slide the
battery cover fully off to the left, remove the old batteries
and fit the new ones WITHIN FIVE MINUTES. Replace
and close the battery cover. The TP5E will continue to
function according to the automatic programme. Should
the display ever become blank during normal operation
the batteries will have to be renewed, the unit RESET,
and the time, day and programme re-set as required.
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Danfoss TP5E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Danfoss TP5E in the language / languages: English as an attachment in your email.

The manual is 0,3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Danfoss TP5E

Danfoss TP5E User Manual - Dutch - 2 pages

Danfoss TP5E User Manual - French - 1 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info