3
Secure the wiring with cable clamps or adhesive tape. To protect the wiring, wrap adhesive tape around them where they lie against
metal parts. To avoid short-circuiting, cover all disconnected lead with insulating tape. There is a possibility of short-circuiting if the
leads are not insulated.
Route and secure all wiring so it cannot touch any moving parts, such as the gear lever and handbrake. Do not route wiring in places
that get hot, such as near the heater outlet. If the insulation of the wiring melts or gets torn, there is a danger of the wiring short
circuiting to the vehicle’s body.
Don’t pass the yellow lead through a hole into the engine compartment to connect to the battery. This will damage the lead’s insula-
tion and cause a very dangerous short.
Do not shorten any leads, if you do, the protection circuit may fail to work when it should.
Never feed power to other equipment by cutting the insulation of the power supply lead of the unit and tapping into the lead. The
current capacity of the lead will be exceeded, causing overheating.
Since a unique audio I/C circuit is employed, never wire so the speaker leads are directly grounded or the left and right - speaker
leads are common.
When this product’s source is switched ON, a control signal is outputted through the orange lead. Connect to an external power amp’s
system remote control or the car’s Auto-antenna relay control terminal (max. 300mA 12V DC). If the car features a glass antenna,
connect to the antenna booster power supply terminal.
When an external power amp is being used with this system, do not connect the orange lead to the amp’s power terminal. Such con-
nection could cause excessive current drain and a major malfunction. Refer to the relevant owner’s manual for details on connecting
the power amp and other units, then make the connections correctly.
Do not block any vents or heater panels, Blocking them will cause heat to build up and may result in fire.
Make sure that the unit has a good chassis ground. A good ground connection will eliminate most electrical noise. A good chassis
ground requires a tight connection to the vehicles metal chassis. The area around the ground connection should be clean, bare metal
without rust, paint, plastic or dirt for a good electrical connection.
If noise is still experienced when the motor of the vehicle accelerates, a choke should be placed in line with the power to the unit.
The installation company will know what is required.
When replacing the fuse(s) the replacement must be of the same amperage as shown on the fuse holder. Never replace a fuse with
another of a different value. If the fuse blows again please contact your instsallation company.
Double check that all wiring and connections are correct before re-connecting the battery and turning on the unit.
After completing the installation and before operating the unit, reconnect the battery, then press the (RES) button with a pointed object,
such as a ball-point pen to set to unit to it’s initial status. After pushing the button, wait a few seconds for the red light to flash.
SAFETY PRECAUTIONS
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Caliber RMD801DAB-BT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Caliber RMD801DAB-BT in the language / languages: English as an attachment in your email.

The manual is 2,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Caliber RMD801DAB-BT

Caliber RMD801DAB-BT Quick start guide - English, German, Dutch, French, Italian, Polish, Portuguese, Swedish, Spanish - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info