3. SAFETY INFORMATION
Hose
Ÿ The hose must be checked for wear or damage before every use and before connecting to the gas container.
Ÿ Do not use the appliance if it has a damaged or worn hose. Replace the hose.
Ÿ Do not use an appliance that is leaking, damaged or which does not operate properly.
Gas Container
Ÿ Ensure that the gas container is fitted or changed in a well-ventilated location, preferably outdoors, away from any sources of ignition
such as naked flames, pilots, electric fires and away from other people.
Ÿ Keep gas containers away from heat and flame. Do not place on a stove or any other hot surface.
Ÿ Gas cartridges/refillable cylinders are to be used only in the upright position so as to ensure proper fuel withdrawal. Failure to adhere to
this may cause liquid discharge from the gas container resulting in a dangerous operating condition.
Ÿ Do not try to remove the cylinder whilst the unit is in operation.
Ÿ The gas cylinder must be disconnected from the appliance after use or when in storage.
Ÿ Not for use with a remote gas supply.
Assembly and use
Ÿ Use only on a firm level surface.
Ÿ Do not move the appliance whilst the unit is in operation.
Ÿ Do not cover up or change the Burner Pan (F) air holes on the Base Plate, as it will influence the flow of air to the Stem Air Holes
located inside the Tripod Housing (J). This, in turn, will affect the performance of the product and may lead to an unstable flame
Ÿ Ensure the appliance is used away from flammable materials. Minimum safe distances are:
Above the appliance 1.2m. At the rear and sides 600mm. (See Fig.1)
Ÿ Caution: Accessible parts may become very hot, the use of protective gloves is recommended.
Ÿ Keep young children away from the appliance.
Ÿ Use Outdoors Only
Light back
Ÿ In the event of light back (where the flame burns back and ignites inside the burner or venturi housing), immediately turn off the gas
supply by firstly closing the control valve on the gas container and then the appliance valve (M). After the flame is extinguished, remove
the regulator and check the condition of the seal; replace the seal if in doubt. Re-light the appliance as described in Section 9 below.
Should the flame persistently light back, return the product to your authorised CADAC repair agent.
Leaks
Ÿ If there is a leak on your appliance (smell of gas), take it outside immediately into a well-ventilated flame-free location where the leak may
be detected and stopped. If you wish to check for leaks on your appliance, do it outside. Do not try to detect leaks using a flame; use
soapy water.
Ÿ The correct way is to smear the joints with soapy water. If a bubble or bubbles form then there is a gas leak. Immediately turn off the gas
supply firstly by closing the control valve on the gas container and then the appliance valve. Check that all the connections are properly
fitted. Re-check with soapy water.
Ÿ If a gas leak persists, return the product to your CADAC dealer for inspection / repair.
Fig. 1
FLAMMABLE
1,2m
FLAMMABLE
600mm
FLAMMABLE
600mm
Model 8309T-13
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cadac 8309 - Grill2Braai at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cadac 8309 - Grill2Braai in the language / languages: English as an attachment in your email.

The manual is 1,88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Cadac 8309 - Grill2Braai

Cadac 8309 - Grill2Braai User Manual - German - 10 pages

Cadac 8309 - Grill2Braai User Manual - Dutch - 10 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info