en - 10 ENGLISH NEDERLANDS/FRANÇAIS/DEUTSCH/ENGLISH nl/fr/de/en - 2
D
E
F
G
C
B
A
Fig. 1 Hoofdcomponenten
A Koudwateraansluiting
B Warmwateraansluiting
C Indicatielamp
D Blokkeerplaat
E Temperatuurknop
F Typeplaat
G Thermostaatas
Fig. 1 Composants principaux
A Raccordement d’eau froide
B Raccordement d’eau chaude
C Lampe témoin
D Plaque de blocage
E Bouton de réglage de la
température
F Plaque signalétique
G Axe du thermostat
Abb. 1 Hauptbauteile
A Kaltwasseranschluß
B Warmwasseranschluß
C Anzeigeleuchte
D Sperrplatte
E Temperaturknopf
F Typenschild
G Thermostatwelle
Fig. 1 Main components
A Cold-water connection
B Hot-water connection
C Indicator
D Locking plate
E Temperature switch
F Type plate
G Thermostat axe
10 Installation
10.1 Installation of the waterheater
Place the device on a flat surface with nothing
in between.
The device may only be installed with
the water connections facing upwards.
10.2 Connections water main
When installing swivels and squeeze
connections, always use 2 open-end
spanners in order to prevent bending
and torsion on the pipes and
accessories.
Pressurised system pressure (Fig. 2.1)
First carefully flush out all the pipes
connecting with the waterheater (especially
important in case of newly-built houses).
Close off the main cock of the water main.
Connect the cold-water connection of the
waterheater (blue) with the inlet combination.
Close off the stop cock of the inlet
combination.
Install a pressure reducing valve upstream of
the inlet combination if the mater main
pressure is higher than the closing pressure
of the inlet combination.
Install the inlet combination or the pressure
reducing valve on the cold-water supply.
• Connect the cold-water connection of the tap
with the cold-watersupply.
Connect the hot-water connection of the
waterheater (red) with the hot-water
connection of the tap.
Unpressurised system (Fig. 2.2)
First carefully flush out all the pipes
connecting with the waterheater (especially
important in case of newly-built houses).
Close off the main cock of the water main.
Connect the cold-water connection of the
waterheater (blue) with the cold-water pipe of
the tap.
Connect the cold-water connection of the tap
with the cold-water supply.
Connect the hot-water connection of the
waterheater (red) with the hot-water
connection of the tap.
10.3 Connection drain pipe
(with pressurised system)
Install an open funnel into the drain pipe
immediately behind the relief valve.
Install a siphon on the drain pipe if this is
connected immediately with the sewer.
10.4 Filling the waterheater
Open the hot-water tap.
Open the stop cock of the inlet combination
(with a system under pressure).
Open the main cock of the water main.
Have the waterheater properly flushed
through.
Check the installation for leakage.
10.5 Connections electricity
The waterheater must be completely
filled with water and the installation
must be free from leaks before a
connection with the electricity grid can
take place.
The device has a three-core cord for a
connection with an earth-connected wall socket.
Fig. 6 Connecting diagram
TR= Temperature regulator
TB= Temperature limiter
N = Zero connection
L = Phase connection
TR TB
L
N
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATAG UKB250 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATAG UKB250 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 0,39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info