702264
2
Zoom out
Zoom in
Previous page
1/10
Next page
No. CON3 CON5
5. Output 4 Output 12
6. Output 5 Output 13
7. Output 6 Output 14
8. Output 7 Output 15
9. Output 8 (HC) Output 16
10. 0 Volts 0 Volts
Technical specifications
Supply voltage
Nominal
10.5 to 13.8 VDC
12 VDC
Current consumption (standby) 50 mA
Open collector output current (each) 50 mA
High current output 1 A
Dimensions (H x W) 90 x 40 mm
Operating temperature
IMQ certified
0 to 50°C
5 to 40°C
Humidity 95%, noncondensing
Regulatory information
Certification
European Union
directives
1999/5/EC (R&TTE directive): Hereby, GE Security
declares that this device is in compliance with the
essential requirements and other relevant provisions
of Directive 1999/5/EC.
2002/96/EC (WEEE directive): Products marked with
this symbol cannot be disposed of as unsorted
municipal waste in the European Union. For proper
recycling, return this product to your local supplier
upon the purchase of equivalent new equipment, or
dispose of it at designated collection points. For more
information see: www.recyclethis.info.
Contact information
For contact information see our Web site: www.gesecurity.eu.
DA: Installations vejledning
Montering af enheden
ATS626 skal monteres på centralprintet ved hjælp af de
medfølgende selv-låsende stag.
Tilslutninger
CON1: Konnektor for plug-on tilslutning til ATS centralen, for
eksempel ATS1000A.
CON3: Konnektor med 7 x 50 mA open collector udgange (nr. 1
til 7) og 1 stk. høj effekt 1A open collector udgang (nr. 8) med intern
pull up modstand. Udgangende er tilgænglige med skrue
terminaler sammen med +12VDC og 0 V (GND) terminaler.
Høj effekt udgangen, kan typisk benyttes som ekstra sirene
udgang, eller tilsvarende.
Note: Strømforbruget fra ATS626 Høj effekt udgangen skal
medregnes akkumulator backup kapaciteten for hele systemet.
Stikket kan også benyttes for tilslutning af ATS1810.
CON5: 8 x 50 mA open collector udgang (9 — 16).
CON6: Bruges ikke.
Tabel 1: Udgang tilslutning - Direkte open collector udgange
Nr. CON3 CON5
1 +12 Volt +12 Volt
2 Udgang 1 Udgang 9
3 Udgang 2 Udgang 10
4 Udgang 3 Udgang 11
5 Udgang 4 Udgang 12
6 Udgang 5 Udgang 13
7 Udgang 6 Udgang 14
8 Udgang 7 Udgang 15
9 Udgang 8 (HC) Udgang 16
10 0 Volt 0 Volt
Tekniske specifikationer
Forsyningsspænding
Norm
10.5 — 13.8 VDC
12 VDC
Strømforbrug (standby) 50 mA
Open collector udgang forbrug (hver) 50 mA
Høj effekt udgang 1 A
Mål (H x B) 90 x 40 mm
Drifttemperatur
IMQ tested
0 to +50°C
+5 to 40°C
Fugtighed 95%, ingen kondensdannelse
Certificering og overholdelse
Certificering
EU-direktiver 1999/5/EC (R&TTE direktivet): GE Security erklærer
herved at dette produkt overholder de væsentlige krav
og andet relevant i detektivet 1999/5/EC.
2002/96/EC (WEEE): Bortskaffelse af elektrisk og
elektronisk udstyr har til formål at minimere den
indvirkning, som affald af elektrisk og elektronisk
udstyr har på miljøet og mennesker. I henhold til
direktivet må elektrisk udstyr, der er mærket med dette
symbol, ikke bortskaffes sammen med almindeligt
husholdningsaffald i Europa. Europæiske brugere af
elektrisk udstyr skal aflevere kasserede produkter til
genbrug. Yderligere oplysninger findes på webstedet
www.recyclethis.info.
Kontakt information
Kontakt information kan findes på Web site: www.gesecurity.eu.
DE: Installationsanleitung
Montage des Einheit
Die ATS626 Erweiterung muß durch Verwendung der
selbstaretierenden Abstandsbolzen auf der Zentralenplatine
installiert werden.
2 of 10 P/N 1068835 • REV 1.0 • ISS 31JUL09
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aritech ATS626 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aritech ATS626 in the language / languages: All languages as an attachment in your email.

The manual is 0,69 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info