537060
5
Zoom out
Zoom in
Previous page
1/16
Next page
Step 5: How to Change & Save your Baby Monitor Settings
IMPORTANT
1. Both the Parent Unit and Nursery Unit have to be turned ON to change monitor settings in the
MENU or SETTINGS screen on the Parent Unit
2. Press the MENU Icon on the Parent Unit screen (see screen B in Step 3c)
3. Press the SETTINGS Icon in the MENU screen to access further settings (see screen C in Step
3c)
4. Change the monitor settings to refl ect personal preferences (see Step 6 to 15)
5. Save the new/changed settings in the MENU or SETTINGS screen on the Parent Unit by
pressing the OK Icon. After pressing the OK Icon, the screen will return to the video capture
screen
6. The Parent Unit screen will return to the video capture screen if no changes have been
recorded in the MENU or SETTINGS screen for 1 minute. Any changes to settings will not be
saved
7. The sound transmission will be temporarily deactivated when monitor settings are being
viewed or changed in the MENU or SETTINGS screen on the Parent Unit. The movement
detection remains activated as normal
IMPORTANT!
If the Icon is illuminated, the relevant Function is activated/ON
If the Icon is dimmed, the relevant Function is deactivated/OFF
MENU ICON:
Access to MENU screen
SETTINGS ICON:
Access to SETTINGS screen
OK ICON:
Save new/changed monitor
settings
TO TEST THE SOUND FUNCTION
Switch both the Parent and Nursery unit ON. Have someone speak into the
Nursery Unit or play music in the baby’s room. You should hear sound from
the Parent Unit. If there is no sound, please refer to the Troubleshooting
section. You can increase/decrease the sound volume using the ARROWS UP
and DOWN on the right hand side of Parent Unit.
TO TEST THE MOVEMENT FUNCTION
1. Make sure the SensorPad is installed correctly and turn both units ON
2. Gently move your hand on top and in the middle of the mattress. This will
simulate your baby’s movements
3. If movement is detected, the pendulum in the Parent Unit Settings Bar will
‘swing’ from left to right
4. After approx. 1 minute remove your hand from the mattress. Do not lean
against the baby’s bed!
5. Due to the lack of movement, the pendulum on the Parent Unit Settings
Bar stops swinging. After 15 seconds a loud ‘pre-alarm’ beep will sound,
and 5 seconds later the alarm will go off (continuous beeping sound)
6. Follow the same process for all four corners of the mattress to ensure that
the SensorPad is covering the complete mattress. The area covered by the
SensorPad can be increased by adjusting the sensitivity (see below)
7. If the alarm does not sound, the SensorPad may be detecting a continuous
vibration from (e.g.) the fl oor, a strong draught or vibrating items (e.g. cot
mobiles), or the baby’s bed is being touched
8. DO NOT touch baby’s bed whilst testing the monitor. Place baby’s bed
near a solid supporting wall and away from strong drafts
TO ADJUST THE SENSITIVITY OF THE SENSORPAD
1. The factory setting is level 3, which is suitable for most baby and
children’s bed sizes and types of mattress. DO NOT ADJUST UNLESS
NECESSARY
2. The sensitivity of the SensorPad can be increased (highest level 5, suitable
for larger beds or thicker mattresses) or decreased (lowest level 1, suitable
for smaller beds and if there a possibility of external vibrations). See Step 8
on how to adjust the SensorPad sensitivity
3. By increasing the sensitivity the SensorPad will cover a larger area (e.g.
bigger beds or thicker mattresses), BUT it could also detect vibrations
from outside the baby’s bed, e.g. mobiles, etc
4. It is important to fi nd the right balance for your situation to ensure optimal
performance of the SensorPad
5. ALWAYS test the performance after moving and reinstalling the Angelcare
Baby Monitor in a different place or when the bed or mattress has
changed
6. NEVER USE THE SENSORPAD WITH AN ADULT MATTRESS, A MEMORY
FOAM OR HOLLOW FRAME MATTRESS!
TO TEST STOPPING THE MOVEMENT ALARM
To stop the alarm:
1. Place your hand on the mattress again so that the SensorPad starts
detecting movement
2. Turn the Nursery Unit OFF (then restart the monitor by turning the Nursery
Unit ON again)
3. Press the Alarm Icon on the Parent Unit screen or press and hold the top
button on the Nursery Unit
TO TEST THE BATTERY MODE
Always check if the battery mode is functioning correctly by operating both
units without the AC adaptors. If the Battery LED is red on the Nursery Unit,
the batteries need to be replaced. If the display on the Parent Unit does not
appear, the Parent Unit needs to be recharged in the Charging Cradle.
IMPORTANT!
The Movement Function is activated as a factory setting. This means
that the Movement Alarm will most likely sound if both the Parent
Unit and Nursery Unit are turned ON for the fi rst time. This is probably
because the SensorPad has not been connected yet or no movement
has been detected, e.g. there is no baby in the (cot) bed yet. This is
normal and shows your Angelcare Baby Monitor works correctly.
Please see Steps 1 to 4 for correct installation and testing of your
Angelcare Baby Monitor to ensure optimal performance.
Step 4: Testing your Angelcare Baby Monitor
Consumer Helpline: 0845 009 1789 | www.angelcare-uk.co.uk
5
AC1100_Manual.indd 5AC1100_Manual.indd 5 19/5/11 2:39:04 pm19/5/11 2:39:04 pm
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Angelcare AC1100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Angelcare AC1100 in the language / languages: English as an attachment in your email.

The manual is 0,61 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Angelcare AC1100

Angelcare AC1100 User Manual - Dutch, Danish - 83 pages

Angelcare AC1100 User Manual - French - 59 pages

Angelcare AC1100 User Manual - Polish, Portuguese, Swedish - 83 pages

Angelcare AC1100 User Manual - Spanish - 59 pages

Angelcare AC1100 User Manual - Finnish - 83 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info