638709
4
Zoom out
Zoom in
Previous page
1/20
Next page
2
3
Fig. 2.1Outline of the LCD
No. Name Description
1 Fan speed Displays the fan speed of the indoor unit: high, medium, low and auto.
2 Operating mode Displays the operating mode of the indoor unit: auto, cool, dry, fan and
heat.
3 System clock Displays the weekday and current time (hour and minute) based on a
24-hour time system.
4 Shield Displays the shielded status, “ALL”, “TEMP”, “MODE” and “ON/
OFF”.
5 Weekly timer Displays the timing period (unit: 0.5 hour) which will cycle each week.
6 Set temperature/Indoor
unit code
Displays the set temperature, indoor unit code (01-16), and the Celsius
or Fahrenheit scale symbols.
7 Control mode Displays “CENTER” under the centralized control mode and no display
under the single control mode.
8 Ambient temperature/
Serial port
Displays the ambient temperature, serial port and the Celsius or
Fahrenheit scale symbols.
9 Indoor unit code/ on/off
status
The indoor unit codes are indicated by numbers which will be displayed
when the corresponding indoor unit is online. “ ” is the indoor unit on/
off status indicator. The unit is “On” when the indicator is lit; the unit is
“Off” when the indicator is not lit.
10 Error , Child lock Displays the error codes when error(s) arise(s) and also “CHILD
LOCK” when this function is activated.
Port 4 (Duct Type)
Port 1 (9RF)
Vired Controller
Port 2 (9RF)
Port 3 (9RF)
Vired Controller Vired Controller
Duct Type
Duct Type
Duct Type
Max.16
Max.16
Max.16
Max.16
Communication Module
Communication Module
Communication Module
Max.16
o
&HQWUDO:LUHG Controller
(Max. 16 indoor units)
PC & Long-Distance Monitoring System
Centralized controller
Fig. 2.2 Introduction to Symbols on the LCD
Table 2.1 Introduction to the Symbols on the LCD
Fig.1.2 Connection of the &HQWUDO:LUHG Controller and the Long-distance Monitoring System/Centralized
Controller
Notes:
c. Only the multi VRF units can be integrated with the long-distance monitoring system/centralized
controller.
d If the shielding function has been set neither for the &HQWUDO:LUHG controller nor for the long-distance
monitoring system/the centralized controller, the &HQWUDO:LUHG controller will be fully compatible with the
long-distance monitoring system/the centralized controller. The &HQWUDO:LUHGs control will be inferior to that
of the latters control.
e When the shielding function has been set for both the FHQWUDOZLUHG controller and the long-distance
monitoring system/the centralized controller, the &HQWUDO:LUHG controller can only be used to view the status of
the unit; its control function will be rendered ineffective.
2. LCD
2.1 Outline of the LCD
Note: the FHQWUDOZLUHG controller can connect with a maximum of three sets of multi VRF units and multiple
duct type units, however, the total of the indoor units of all four ports may not exceed 16.
1.2.2 Integration of the &HQWUDO:LUHG Controller and Long-distance Monitoring System/
Centralized Controller.
2.2 Introduction to Symbols on the LCD
Confirm/Cancel
Mode
Fan
On/Off
Timer/Time Central
Shield
Mon
Tue
Wed Thu
FriS at Sun
24 68 10 12 14 16 18 20 22 24



9
10
1112
1314
1516
CENTER
SUNMON TUEW ED THUF RI SAT
AUTO
SUN
MON
TUE
WED
THU
FRISAT
SHIELD
CHLD LOCKI
ERROR
ROOM
COM
SET
INNER UNIT
TEMP
MODE
ON/OFF
ALL
AllonAlloff
Fan
AllonAlloff
Confirm/Cancel
Mode
Fan
On/Off
Timer/Time Central
Shield
Mon
Tue
Wed Thu
FriS at Sun
24 68 10 12 14 16 18 20 22 24



9
10
1112
1314
1516
CENTER
SUNMON TUEW ED THUF RI SAT
AUTO
SUN
MON
TUE
WED
THU
FRISAT
SHIELD
CHLD LOCKI
ERROR
ROOM
COM
SET
INNER UNIT
TEMP
MODE
ON/OFF
ALL
AllonAlloff
Fan
AllonAlloff
&(175$/:,5('&21752/&(175$/:,5('&21752/
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Airwell RCW4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Airwell RCW4 in the language / languages: English as an attachment in your email.

The manual is 3,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info