&(175$/:,5('&21752/
5.3.6 Time ...................................................................................................................................16
5.3.7 Shield
.................................................................................................................................18
5.3.8 Child Lock
......................................................................................................................... 25
5.3.9 Switching between Celsius and Fahrenheit
....................................................................... 26
6 Error Display .........................................................................................................................26
7 Installation and Debugging
.............................................................................................29
7.1 Installation ..............................................................................................................29
7.1.1 Installation Dimension Diagram........................................................................................29
7.1.2 Interfaces
...........................................................................................................................29
7.1.3 Preparation and Connection of the Communication Line
.................................................30
7.1.4 Installation
.........................................................................................................................30
7.2 Unit Matching ........................................................................................................32
7.3 Debugging and Viewing the Port No. and the Indoor Unit Address ......................32
7.4 Labeling .................................................................................................................33
Vired
Controller
&HQWDO:LUHGe
Controller
Duct Type
Vired
Controller
Vired
Controller
Duct Type Duct Type
Port 1 (VRF)
Max. 16
Max. 16
Max. 16
Port 2 (VRF)
Port 3 (VRF)
Port 4 (Duct Type)
Max. 16
Fig. 1.1 Unit Connection Diagram
1. General Introduction
1.1 Function Introduction
The FHQWDOZLUHG controller is intended for multi VRF units and duct type units, capable of controlling
up to 3 sets of multi VRF units and multi sets of duct type units with a maximum of 16 indoor units.
The FHQWUDOZLUHG controller enables viewing and controlling of the indoor unit operating parameters,
including on/off, operating mode, fan speed, etc. The controller implements the single control and
centralized control and can also set the weekly timer and long-distance shielding, allowing for
convenient control of the air conditioning system.
a. Single control: designed to control the operating parameters of an individual, designated indoor
unit.
b. Centralized control: designed to control the operating parameters of all indoor units at the same
time.
c. Shielding under single or centralized control: designed to shield the operating parameters of the
indoor unit.
d. Weekly timer under single or centralized control: designed for remote controlled start/stop
programming of the unit.
e. Clock: Designed for setting and display of the current weekday, hour and minute.
Following controller debugging completion, the debugger can check the on-line indoor units and
display the parameter settings of the current operating mode: set temperature, fan speed, weekly timer,
shielding function, etc. When an error occurs, the error symbol and the error code will be displayed to
warn for the need for immediate maintenance.
The FHQWUDOZLUHG controller can be connected to the unit through the communication line without the
need for the communication module, immensely easing and simplifying the installation.
This FHQWUDOZLUHG controller can be integrated with the long-distance monitoring system and the
centralized controller (it indicates the controller that should be equipped with the communication
module). The control of the long-distance monitoring system and the centralized controller take
priority over that of the smart zone controller.
1.2 Communication Network
1.2.1 Units Connections
Max. 16
Confirm/Cancel
Mode
Fan
On/Off
Timer/Time Central
Shield
Mon
Tue
Wed Thu
FriS at Sun
24 68 10 12 14 16 18 20 22 24



9
10
1112
13 14
15 16
CENTER
SUNMON TUEW ED THUF RI SAT
AUTO
SUN
MON
TUE
WED
THU
FRISAT
SHIELD
CHLD LOCKI
ERROR
ROOM
COM
SET
INNER UNIT
TEMP
MODE
ON/OFF
ALL
AllonAlloff
Fan
AllonAlloff
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Airwell RCW4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Airwell RCW4 in the language / languages: English as an attachment in your email.

The manual is 3,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info