Energy consumption monitoring
The thermostat calculates the average switch-on time thus making it possible to monitor energy consumption.
The thermostat displays the energy consumption as a percentage for the last 2, 30 or 365 days.
Calculation of operational costs per day: (switch-on time:100) x kW x kWh price x 24 hours per day.
Example: 30% displayed for the last 365 days.
Heating system wattage: 0.32 kW (e.g. thermo floor 2 m2 with 160 W/m2).
Power costs 0.15 EUR / kWh
Calculation (30:100) x 0.32 kW x 0.15 EUR / kWh x 24 hours = 0.35 EUR per day.
5. Special settings and displays
Time program
The selected time program flashes: Days 1–5 followed by days 6–7. To change this setting, press the UP button until days 1-6
and then day 7, or all 7 days are flashing. Select the required time program by pressing the OK button.
OK
-
5-2: 4 time programs over 5 days +
}
factory setting
2 time programs over 2 days
6-1: 4 time programs over 6 days +
2 time programs over 1 day
7-0: 4 time programs over 7 days
OK
-
}
2 days
30 days
365 days
Software Version
Regulation sensor
}
Press the UP and DOWN buttons at the same time for 5 seconds. INFO is displayed. Press the UP button until the required submenu
is displayed. Select the submenu by pressing OK.
Press UP or DOWN to show
the different displays. No
changes can be made here.
Press the OK button to leave
the menu.
Function program (factory setting)
Limit sensor (only displayed when the function roLi is selected)
Function selection
The electronic comfort thermostat FRTD 902 features an integrated and an external temperature sensor.
FRTD 902 can be programmed as a floor thermostat with floor sensor or as a room thermostat with limit function.
Upon delivery the thermostat is programmed as a Flo floor thermostat.
OK
-
In this configuration the temperature is regulated by means
of a built-in room sensor and a floor sensor for limitation.
Floor sensor with 3 m connecting cable.
In this configuration the temperature is only regulated by
means of a floor temperature sensor. Floor sensor with 3 m
connecting cable.
}
Maximum and minimum permissible temperatures on floor surface
The maximum value is used to prevent the floor temperature from rising too much, e.g. in connection with wooden floors that cannot
withstand temperatures in excess of 27°C. This value can be set between 5-40°C.
The minimum value is used to prevent the temperature in for example kitchens and bathrooms from falling below the set
temperature. This value can be set between 5-40°C. The value can be deactivated (ON/OFF) by setting the temperature to 5°C and
pressing the DOWN button again.
Please note that the maximum value must be higher than the minimum value.
OK
-
Max. permissible temperature. Press the UP or DOWN
button to increase or lower the value. Press OK to
confirm the setting.
LSLO is then displayed. Press the OK button to
continue.
Min. permissible temperature. Press the UP or DOWN
button to increase or lower the value. Press OK to
confirm the setting.
Temperature range limitation
The temperature range from +5°C to 35°C can be limited in order to prevent the selection of a temperature that is either too high or
too low.
Max. temperature setting
Press the UP or DOWN button to increase or lower the
value. Press the OK button to accept the setting.
LoLi is then displayed. Press the OK button to continue.
Min. temperature setting
Press the UP or DOWN button to increase or lower the
value. Press OK to accept the setting.
OK
-
OK
-
OK
-
OK
-
OK
-
OK
-
OK
-
OK
-
OK
-
OK
-
OK
-
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for AEG FRTD 902 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of AEG FRTD 902 in the language / languages: English, German as an attachment in your email.

The manual is 2,21 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of AEG FRTD 902

AEG FRTD 902 Installation Guide - English, German - 8 pages

AEG FRTD 902 User Manual - Dutch - 8 pages

AEG FRTD 902 Installation Guide - Dutch, French - 8 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info