Section 61180019L1-5A
Issue 1, May 2004
CLEI Code: VAM5500F_ _
61180019L1-5A 1
Trademarks: Any brand names and product names included in this document are
trademarks, registered trademarks, or trade names of their respective holders.
Figure 1. Total Access 1500 19-Inch Chassis
CONTENTS
1. General .................................................................... 1
2. Installation............................................................... 3
3. Maintenance .......................................................... 13
4. Specifications ........................................................ 13
5. Warranty and Customer Service ........................... 14
FIGURES
Figure 1. Total Access 1500 19-Inch Chassis............. 1
Figure 2. Flush-Mount Bracket Orientation................ 4
Figure 3. Mid-Mount Bracket Orientation .................. 4
Figure 4. Power and Ground Connectors.................... 5
Figure 5. Backplane and Pinouts................................. 6
Figure 6. Ring Generator Terminal............................. 7
Figure 7. Daisy-Chained Composite Clock Wiring .... 8
Figure 8. Alarm Contacts .......................................... 10
Figure 9. RS-485 Wiring........................................... 12
TABLES
Table 1. Compliance Codes ........................................ 2
Table 2. Specifications .............................................. 13
1. GENERAL
This practice is an installation and maintenance guide
for the ADTRAN Total Access 1500
®
19-Inch Chassis
(P/N 1180019L1). Figure 1 illustrates the a populated
19-Inch Chassis.
Revision History
This is the initial issue of this practice. Future changes
to this documentation will be explained in this
subsection.
Features
The basic features of the Total Access 1500 19-Inch
Chassis include the following:
Rackmount design
Scalable network connectivity
1-5 T1 capacity (4 T1s and a Protect T1 for TR-08
applications utilizing a Quad LIU)
Three common modules:
Power Supply/Ring Generator Unit (PSU/RGU)
System Controller Unit (SCU)
Line Interface Unit (LIU)
T1 Network Interface
18 slots for combination of voice and data services
Variety of access module units
Network management capabilities (TL1, SNMP)
Multiple configuration arrangements
TR-08 compatible (Modes 1, 2, and 3)
Supports Mechanized Loop Testing (MLT)
NRTL Safety Listed and FCC compliant
Meets NEBS Level 3 requirements
Description
The Total Access 1500 19-Inch Chassis is designed to
meet a variety of operating configurations and services,
such as POTS and Special Services. The Total Access
1500 19-Inch Chassis is intended for use in Central
Office (CO), Remote Terminal (RT), and customer
premises applications. The Total Access 1500 System is
comprised of the chassis, common modules, and access
modules.
Total Access 1500 19-Inch Chassis
Installation and Maintenance Practice
PSU-A PSU-APSU-B SCU 1 2 3 4 5 6 7 8 9 10 11 12 1413 15 16 17 18LIU-B
1180008L2
POTS RTPOTS RTPOTS RTPOTS RTPOTS RTPOTS RTPOTS RTPOTS RTPOTS RTPOTS RTPOTS RTPOTS RTPOTS RTPOTS RTPOTS RTPOTS RTPOTS RTPOTS RT
1180007L3
1180007L3
1


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Adtran total access 1500 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Adtran total access 1500 in the language / languages: English as an attachment in your email.

The manual is 4,25 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info