We reserve the right to make changes to dimensions and construction 29 Edition 10.07.2015
© Copyright YGNIS AG CH-Ruswil
10. Maintenance
maintenance or cleaning work can be carried out on the boiler or burner by the operator. The following points
must be observed for optimum operation:
- The combustion chamber must be kept clean
- A fresh air supply must always be guaranteed
- The connection between the waste gas pipes of the condensing unit and the waste gas unit must be gas and
condensate leak-tight.
Periodical checks and maintenance operations
- Check manometer with circulation pump off. Low water or pressure level indicates that the system must be
filled up with water. Observe the required water quality according chapter 4.2.
- Check that the expansion chambers function properly
- Check safety valves as well as heating and hot water system blowers
- Check the internal siphon of the unit in the condensate drain. It must be filled with water.
- Clean the air filter(s) (and check the gas filter on the optional 300 mbar version)
- Boiler and chimney cleaning: The waste gas collector of the condensing unit is equipped with a cleaning
cover for the activities of the chimney sweep. After this person has finished his work, make sure that the
cover is carefully mounted, in order to prevent the uncontrolled escape of waste gases and condensate as
well as intrusion of air (which results in an incorrect O2 signal).
- The water chamber below the heat exchanger is equipped with a cleaning cover. After you have drained the
boiler water, this cover allows you to check whether sludge has collected in the boiler. Use the scraper
delivered with the unit to remove the sludge. Then carefully close the cover. Refill while observing the
required water quality according chapter 4.2. After you have refilled the system, check for leaks.
The devided version of the boiler (VG-TB) is furthermore equipped with an inspection cover above the heat
exchanger. The packing of this cover is to be checked for tightness during the annual boiler inspection.
- Annual general boiler and burner check by the customer service.
Notes: Cleaning work on the boiler is normally not required and may only be carried out after having
dismantled the igniter and the O2-sensor.
Dismantling and reinstallation of the burner are to be carried out in accordance with instructions from
the manufacturer.
Maintenance work on the burner may only be carried out by specialists trained on the product.
The device contains components made of synthetic silicon mineral fibres (glass fibres, insulation
wool). In order to avoid all types of health hazards, suitable clothing and a protective mask must be
worn for work on or with these components.
11. Spare parts
Available at your customer service.
31


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ygnis VARINO GRANDE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ygnis VARINO GRANDE in the language / languages: English as an attachment in your email.

The manual is 1,43 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Ygnis VARINO GRANDE

Ygnis VARINO GRANDE Installation Guide - English, German, Dutch - 48 pages

Ygnis VARINO GRANDE Usermanual and installation guide - Dutch - 34 pages

Ygnis VARINO GRANDE Installation Guide - French, Italian, Spanish - 48 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info