Troubleshooting
If you encounter problems such as no sound output or abnormal behavior, verify the connections
before checking the following. If you are using Voice Editor for Windows, refer to the host
application's owner’s manual (online manual) too.
<Macintosh>
The printer port is not recognized.
The printer port will not be recognized if
AppleTalk is ON. Note that with some Macintosh
models, AppleTalk is automatically enabled when
starting up.
•Verify that the “Printer” checkbox has been
checked in the OMS MIDI Setup window.
The modem port is not recognized.
On some Macintosh models such as the
Performa series, the modem port cannot be used
and only the printer port is available.
•Verify that the “Modem” checkbox has been
checked in the OMS MIDI Setup window.
No MIDI In/Out data
Is the MIDI device’s "HostSelect" setting (UTILITY
PAGE 13) set correctly?
Make the correct setting according to the
instructions in your synthesizer's Owner’s
Manual.
In the OMS Port Setup, is MIDI In/Out set to
“unknown”? If you change the OMS ports or
setup, the OMS output ports have to be set
accordingly in Voice Editor’s OMS Port Setup
window. Choose the appropriate receiving
device.
Is OMS using the same port as that connected to
the cable? Open the OMS MIDI Setup window
and verify that the checkbox for the relevant port
has been checked.
If the port and setup assignments are frequently
altered, OMS may be unable to easily recognize
the serial port. Reboot the Macintosh, set up
OMS correctly, then start up Voice Editor.
Bulk data are not received.
Open the OMS Port Setup window and check
that the MIDI In has been properly assigned
(page 24).
Open the Editor Setup Dialog and check that the
Device No. has been properly assigned (page 10).
Voice Editor does not start up when Library File
(extension .S6V) is double-clicked.
Change the Type/Creator settings for Library
Files as follows, then try double-clicking the file
again.
Type: S6V_
Creator: YS08
<Windows>
Bulk data is not received.
The MIDI In port in Editor Setup can be chosen
from the MIDI In ports in the settings of the host
application. Check the MIDI In settings in the
System Setup of the host application.
Open the Editor Setup Dialog and check that the
Device No. has been properly assigned (page 10).
Depending on your host application, you may
need to set the application’s MIDI Thru port setting
to off.
MIDI Out port is not available in Editor Setup.
The MIDI Out port in Editor Setup can be chosen
from the MIDI Out ports in the setting of the host
application. Check the MIDI Out settings in the
System Setup of the host application.
<Windows / Macintosh>
Sound does not change when using knobs or
sliders.
Are the MIDI Out port and Device Number set
correctly in the Editor Setup? (
page 10
)
Bulk data is not transmitted.
Are the MIDI Out port and Device Number set
correctly in the Editor Setup? (
page 10
)
Is the Dump Interval in the Editor Setup too
short? Make sure the Dump Interval is at least 10
ms.
Sound is doubled when playing keyboard.
On your synthesizer, switch Local to OFF.
No sound heard when clicking on-screen
keyboard in Edit Window.
Is the MIDI Ch. set correctly in the Editor Setup?
(page 10)
Sound does not change when Monitor button is
pressed.
Are the MIDI Out port and Device No. set
correctly in the Editor Setup (OMS Port Setup)?
(
page 10
and 24)
S08 Library files can’t be directly loaded to the
S08 from a Memory card.
The file name should included the extension
“.S6V”
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Yamaha S08 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Yamaha S08 in the language / languages: English as an attachment in your email.

The manual is 0,4 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Yamaha S08

Yamaha S08 Installation Guide - English - 24 pages

Yamaha S08 User Manual - English - 88 pages

Yamaha S08 User Manual - German - 26 pages

Yamaha S08 Installation Guide - German - 24 pages

Yamaha S08 User Manual - German - 88 pages

Yamaha S08 User Manual - French - 26 pages

Yamaha S08 User Manual - French - 88 pages

Yamaha S08 Installation Guide - French - 24 pages

Yamaha S08 User Manual - Italian - 88 pages

Yamaha S08 Installation Guide - Italian - 8 pages

Yamaha S08 User Manual - Portuguese - 89 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info