Page 60 FT-897D OPERATING MANUAL
MENU MODE No054
[
LOCK MODE
]
Function: Selects the operation of the front panel’s LOCK
key.
Available Values: DIAL/FREQ/PANEL/ALL
Default: DIAL
DIAL: Locks the DIAL knob only.
FREQ: Locks the front panel keys and knobs related to
frequency control (such as BAND
(
UP
)
and
BAND
(
DWN
)
key,
[
A
](
A/B
)
key., etc.)
PANEL: Locks all front panel keys and knobs (except
POWER and LOCK keys)
ALL: Locks all front panel keys and knobs (except
POWER and LOCK keys) and microphone keys.
MENU MODE No055
[
MEM GROUP
]
Function: Enables/disables the memory grouping feature.
Available Values: OFF/ON
Default: OFF
When this Menu Item is set to “ON,” the 200 “standard”
memory channels are partitioned into ten Memory Groups,
each holding up to 20 memory channels.
MENU OPERATION
tarily, then rotate the MEM/VFO CH knob, as needed,
until Multi Function Row “b”
[
MW, MCLR, TAG
]
ap-
pears on the display. Press the
[
C
](
TAG
)
key momen-
tarily to activate the alpha-numeric Tag. Repeatedly
pressing this key will toggle operation between “Fre-
quency” display and “Tag” display.
You can recall Menu Mode No-056 [MEM
TAG] instantly by pressing and holding in the
[C](TAG) key for one second.
MENU MODE No057
[
MEM/VFO DIAL MODE
]
Function: Selects the function which is engaged when you
press the MEM/VFO CH knob.
Available Values: CW SIDETONE, CW SPEED, MHz/
MEM GRP, MIC GAIN, NB LEVEL, RF POWER/STEP
Default: MHz/MEM GRP
MENU MODE No058
[
MIC SCAN
]
Function: Enables/disables scanning access via the
microphone’s [UP]/[DWN] keys.
Available Values: OFF/ON
Default: ON
MENU MODE No059
[
MIC SEL
]
Function: The choice of the equipment which connects to
the MIC jack.
Available Values: NOR/RMT/CAT
Default: NOR
NOR:Normal Microphone.
RMT:Optional MH-59A8J Remote Microphone.
CAT: CAT system: if you are using the op-
tional FC-30 antenna tuner, you can
still use the CAT system by connect-
ing the serial Data cable to the MIC
jack.
MENU MODE No060
[
MTR ARX SEL
]
Function: Select the meter display configuration while the
transceiver is receiving.
Available Values: SIG, CTR, VLT, N/A, FS, OFF
Default: SIG
SIG: Indicates the incoming signal strength.
CTR: Discriminator center meter.
VLT: Indicates the battery voltage.
N/A: Not available at this time.
FS: Applies a calibration signal (1 mA for full scale) at
the METER Jack on the transceiver bottom, for ad-
justment of an external meters calibration.
You may adjust the external potentiometer in your
metering system so that the external meter reading is
full scale.
OFF: Disables the meter.
RXD GNDTXD
MENU MODE No056
[
MEM TAG
]
Function: Stores Alpha-Numeric “Tags” for the memory
channels.
Up to eight characters may be stored. The storage proce-
dure is as follows:
1. Recall the memory channel onto which you wish to ap-
pended a label.
2. Press and hold in the
[
F
]
key for one second to enter the
Menu mode.
3. Rotate the MEM/VFO CH knob to recall Menu Mode
No-056
[
MEM TAG
]
.
4. Press the MEM/VFO CH knob to enable the program-
ming of the label.
5. Rotate the DIAL knob to select the first character (num-
ber, letter, or symbol) in the name you with to store, then
rotate the MEM/VFO CH knob clockwise to move to
the next character.
6. Again rotate the DIAL knob to select the next number,
letter, or symbol, then rotate the MEM/VFO CH knob
clockwise to move to the next characters slot.
7. Repeat step 6 as many times as necessary to complete
the name tag for the memory, then press and hold in the
[
F
]
key for one second to save the A/N (Alpha-Numeric)
name entry and exit to normal operation.
8. During Memory operation, press the
[
F
]
key momen-
MEMORY GROUP “OFF”
M-001 ~ M-020
M-021 ~ M-040
M-041 ~ M-060
M-061 ~ M-080
M-081 ~ M-100
M-101 ~ M-120
M-121 ~ M-140
M-141 ~ M-160
M-161 ~ M-180
M-181 ~ M-200
M-P1L ~ M-P5U
MEMORY GROUP “ON”
Ma-01 ~ Ma-20
Mb-01 ~ Mb-20
Mc-01 ~ Mc-20
Md-01 ~ Md-20
Me-01 ~ Me-20
Mf-01 ~ Mf-20
Mg-01 ~ Mg-20
Mh-01 ~ Mh-20
Mi-01 ~ Mi-20
Mj-01 ~ Mj-20
Mk-1L ~ Mk-5U
MEMORY CHANNEL NUMBER
62


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Yaesu FT-897D at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Yaesu FT-897D in the language / languages: English as an attachment in your email.

The manual is 3,3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info