745738
6
Zoom out
Zoom in
Previous page
1/60
Next page
6
Skorsten
75
min.15
150
Porebeton
dette, hvorfor den lokale skorstensfejermester skal træffe det endelige valg.
Fig. 1 (mål i mm)
Generelt
Cubic skal monteres, indbygges eller hænges minimum 20 cm over et brændbart gulv.
Dette gælder også selvom, at der placeres en gulvplade oven gulvet. Der skal være en
afstand 15 mm hele vejen rundt om ovnen (også under ovnen) for at sikre tilstrækkelig
tilførsel af konvektionsluft. Over ovnen skal der være et antal konvektionshuller, hvor den
opvarmede luft kan passere. Hullerne skal minimum have et samlet areal 200 cm
2
.
Umiddelbart over hullerne skal der monteres en plade, der lukker konvektionskanalen.
Monteres WIKING Cubic med topafgang skal pladen slutte tæt til skorstenen. Vi anbefaler,
at sprækken rundt om skorstenen maksimalt er 5 mm., og vi anbefaler, at konvektionshul-
lerne placeres minimum 800 mm under loftet. Se fig. 2.
Fig. 2
800 mm
15 mm afstand
Der kan laves plads for lagring af brænde og andre brændbare genstande i indbygningen.
Brænde kan lagres umiddelbart under brændeovnen. Ønskes plads til lagring ved siden
af ovnen skal der i princippet være en afstand 350 mm til ovnen. I praksis laves ofte
indbygninger, hvor brændet lagres væsentlig nærmere ovnen adskilt af en ikke brænd-
bar plade. Teknologisk Institut har lavet en temperaturmåling på ydersiden af en 100 mm
gasbetonvæg monteret 100 mm fra ovnen som vist fig. 3. Temperaturen blev målt til
maksimalt 29 °C ved en rumtemperatur 20 °C. Temperaturen blev målt kontinuerligt med
et termoelement type K. Det er den lokale skorstensfejermester, der skal give dispensation
fra afstandskravet på 350 mm. Ovennævnte test er til skorstensfejerens information.
Der er krav om, at skorstensfejeren skal kunne syne stålskorstenen helt op til loftet. Der skal
derfor være indbygget en rist eller lem ved den øverste del af stålskorstenen, hvorigennem
skorstensfejeren med et spejl kan se skorstenen. Tag kontakt til den lokale skorstensfejer
for at afklare den endelige placering.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wiking Cubic at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wiking Cubic in the language / languages: German, Danish, Italian, Swedish, Norwegian as an attachment in your email.

The manual is 0,94 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info