Remove the perimeter extraction panel (if relevant) and the grease filter/s.
Pre-assemble the steam deflector on the motor assembly (if relevant): (a.) fit the steam deflector to the rails of the motor
assembly (remove the two travel stop screws from the steam deflector if necessary), (b.) connect up the control panel and
the lamps, (c.) fix in place with the 14 screws (max).
1. Mark a line on the wall right up to the ceiling, corresponding to the centre-line of the hood.
2. Apply the drilling template to the wall: Align the vertical centre-line on the drilling template with the centre-line drawn
on the wall. The template's bottom edge represents the bottom edge of the hood.
3. Place the mounting bracket over the drilling template so that it matches the outlined rectangle. Mark and drill the two
outside holes. Remove the drilling template. Insert two wall plugs in the holes and fix the hood mounting bracket in place
with two 5 x 45 mm screws.
4. Hang the hood on the mounting bracket. Adjust gap (5.) and the horizontal alignment (6.) of the hood.
5. Remove the hood from the bracket. Drill the holes (9. - Ø 8 mm - see step 7.). Insert two wall plugs (10.).
6. Apply the flue mounting bracket G to the wall against the ceiling. (Align the small slot in the bracket with the centre-line
drawn on the wall. See step 1. Fix the bracket in place with two wall plugs (Ø 8 mm) and 2 screws 12).
7. Hang the hood on the bottom mounting bracket. (14.) Fix the hood to the wall with two 5 x 45 mm screws
(ABSOLUTELY NECESSARY). Plug the two holes if they are visible from the outside.
8. Connect an exhaust pipe to the to the collar B, the fumes must be ducted to the outside (extractor version) or towards
the deflector (filter version). Fix the deflector F to the flue support bracket G with 4 screws (2 screws only for 120 cm
wide model). If the collar (bayonet coupling) is not already fitted, insert it on the deflector F and secure it with 1 screw.
9. Make all necessary electrical connections.
10. Apply the flues and fix them with 2 screws (17a) to the flue support G (17b).
11. Slide the bottom section of the flue all the way over the extraction unit until it engages the seat above the hood.
12. (120 cm wide model only) fix the bottom section of the flue to the hood with 2 screws.
Re-fit the grease filter/s and, if a perimeter extraction panel is fitted, check for correct operation.
Important! Only for model AKR 996: proceed with hob selection and manual calibration of the sensors. For this purpose,
read the paragraph on the next page Important - upon initial installation”.
6
1. Control panel.
2. Grease filter.
3. Halogen bulbs.
4. Steam deflector.
5. Telescopic flue.
6. Perimeter extraction
panel (if fitted) and
release handle (f3).
7. Sensors (only present on
some models).
INSTALLATION - ASSEMBLY INSTRUCTIONS
IF NL E PGBD GR
31833157.fm Page 8 Friday, April 1, 2005 5:04 PM
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Whirlpool AKR 812 IX at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Whirlpool AKR 812 IX in the language / languages: English as an attachment in your email.

The manual is 0,78 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Whirlpool AKR 812 IX

Whirlpool AKR 812 IX User Manual - English - 6 pages

Whirlpool AKR 812 IX Installation Guide - English - 6 pages

Whirlpool AKR 812 IX User Manual - German - 4 pages

Whirlpool AKR 812 IX Installation Guide - German - 6 pages

Whirlpool AKR 812 IX Installation Guide - German - 6 pages

Whirlpool AKR 812 IX Installation Guide - Dutch - 6 pages

Whirlpool AKR 812 IX User Manual - Dutch - 4 pages

Whirlpool AKR 812 IX Installation Guide - French - 6 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info