802458
4
Zoom out
Zoom in
Previous page
1/4
Next page
Note Comment
1 Not present when the system was activated via the external preset
timer.
2
Switches the auxiliary heating or auxiliary ventilation on at the
programmed time for the programmed operating period.
IMPORTANT: Only one heating or ventilation process is activated.
For a repeat process, another activation of the preset timer is
required.
3 If no entry is made within 10 seconds, ThermoCall automatically
returns to the main menu.
4
If the entry was incorrect or no entry is made within 5 seconds,
ThermoCall returns to the programming menu with the message
“INCORRECT ENTRY”. The previous setting remains unchanged.
5
The entered minute value is saved as the new operating period for
the auxiliary heating or auxiliary ventilation. At the factory, the
heating and ventilation periods are set to 30 minutes.
6 If an external GPS- Modul is attached
Character Legend
01234
56789 Telephone keys (see telephone manual)
Press key(s)
“xx” ThermoCall text
# “Hash” key
ł Blank space (see telephone manual)
Less than or equal to
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Webasto ThermoCall TC1.1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Webasto ThermoCall TC1.1 in the language / languages: English as an attachment in your email.

The manual is 0.19 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Webasto ThermoCall TC1.1

Webasto ThermoCall TC1.1 User Manual - German - 4 pages

Webasto ThermoCall TC1.1 User Manual - Dutch - 4 pages

Webasto ThermoCall TC1.1 User Manual - French - 4 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info