805473
3
Zoom out
Zoom in
Previous page
1/20
Next page
3
3. Installation and RF Initialisation rules
Install and connect the receiver respecting the following guidelines to guarantee an optimal reception:
- The receiver must be mounted at a minimum distance of 50cm of all others electrical or wireless materials like GSM, Wi-Fi
router.
- Wiring work related to the receiver must be carried out only when de-energized
- Connect your receiver to the power supply.
Depending on your installation, an order of pairing must be respected to ensure a correct RF signal transmission.
Installation 1: Receiver + RF thermostat
1. Switch on the receiver.
2. Press the RF button during 3 sec to switch to RF Init.
3. The RF LED should be Green fixed or orange blink indicating that the Receiver is now in radio configuration mode waiting for
a thermostat configuration address.
4. Please refer to the thermostat leaflet for enter the thermostat in “RF Init” mode.
5. The receiver RF LED must be switched OFF and the thermostat should exit the RF init mode to indicate correct paring
between both elements.
You can pair several receivers to the same RF thermostats
Note for installations 2 and 3: You can pair several receivers. Pay attention! Before linking a new receiver with the Central unit,
you have to reset the receiver imperatively.
Installation 2: Receiver + RF Thermostat + RF Central unit for heating regulation
1. First step is to pair the RF thermostat to the Central unit
2. Press the RF button on the receiver during 3sec.
3. The RF LED should be Green fixed or orange blink indicating that the Receiver is now in radio configuration mode waiting for
a central configuration address.
4. Please refer to the leaflet of the Central unit for more explanation about the pairing mode “RF Init”. You must pair the Receiver
as a heating device in the Central unit
5. The RF LED on the receiver will switch OFF and the Central will show a message to indicate correct pairing between both
elements.
You can pair several receivers in the same room.
Installation 3: Receiver + RF Central unit for ON/OFF or light control
1. Press the RF Button 3sec to switch the Receiver in RF Init mode .
2. The RF LED should be Green fixed or orange blink indicating that the Receiver is now in radio configurationmode waiting for a
central configuration address.
3. Please refer to the leaflet of the Central unit for more explanation about the pairing mode “RF Init”. You must pair the Receiver
as an ON/OFF plug or a light in the Central unit
4. The RF LED on the receiver will switch OFF and the Central will show a message to indicate correct pairing between both
elements.
You can pair several receivers in the same room. Receiver will work in Timer mode; you have the possibility to create a weekly
program for ON/OFF period.
Remarks:
- In case of a thermostat in RF Alarm, the receiver (BT-FR02 RF or BT-WR02 RF) will follow 20% cycle of heating to prevent the
installation against frost. (The receiver will stay in OFF mode if it was in OFF before the loss of RF communication).
- Plug receiver, Flush receiver, Wall receiver: The leds are switched off between 8pm and 8am when using a BT-DP02 RF/ BT-
DP03 RF.
You can drive directly up to 2300W (10A) with your receiver BT-WR02 RF,
Mounting instruction:
- For security reason and easy mounting we recommend to connect only one radiator to each receiver.
- If your installation uses the pilot wire, don’t forget to active the Pilot Wire function on the parameter menu of BT-XX02 RF
or BT-XX03 RF thermostat.
EN
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Watts WR02 RF - free contact Wireless Wall Receiver at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Watts WR02 RF - free contact Wireless Wall Receiver in the language / languages: English, German, Dutch, Danish, French, Italian, Swedish, Spanish, Norwegian as an attachment in your email.

The manual is 0.93 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info