RF basic thermostat WFHTRF 010 (20433)
TECHNICAL CHARACTERISTICS
MODES DESCRIPTION
- Radio frequency RF thermostat (433.92 Mhz) specially designed for
water floor heating. (Personal code on each product)
- Equipped with a LCD display to select comfort (
), Off or night
reduction (
) mode.
- Setting and room temperature displayed.
- To be used only with ours receivers.
PPL IMP 1014A
Measured temperature
precision
0.1°C (or 0.2°F)
Operating temperature 0°C - 50°C (or 32°F – 122°F)
Setting temperature range
5°C - 37°C by 0.5°C step
(or 41°F - 99°F by 0.5°F step)
Regulation characteristics
Proportional Integral regulation (adjustable see installation
menu) Cycle: 15 minutes or
Static differential 0.3°K
Anti-short cycle: 3min in OFF, 2min in ON.
Electrical Protection Class II - IP30
Power Supply
Battery operated life
2 x 3V (CR2430)
~ 2 years
Radio frequency 433.92 MHz, <10mW.
certifications
CE. EN 300220-1, EN 301489-1
(Radio frequency certifications)
Soft version Displayed when the thermostat is turn Off
RADIO CONFIGURATION MODE
- To assign (*) the RF thermostat with the receiver you must put the
receiver in “RF init” mode (please refer to the receiver leaflet).
- After you have just Press “Ok” key during 5 sec, when the display( rF “”)
The thermostat sends its configuration address by radio signal.
- When the receiver is configured, Press “Ok” key to return to user menu.
* (In this mode the thermostat should be near the receiver)
COMFORT operating mode:
Force comfort temperature operation
indefinitely.
By pressing +/- keys the comfort
temperature starts to blink and can be
adjusted.
The measured temperature
reappears after a few seconds.
OFF mode:
Use this mode if your Heating
installation needs to be turned OFF.
The display is blank.
(Careful in this mode your installation
can freeze)
Parameters are saved.
REDUCED operating mode:
Force reduced temperature operation
indefinitely.
By pressing +/- keys the comfort
temperature starts to blink and can be
adjusted.
The measured temperature
reappears after a few seconds.
1: Operating mode menu
2: Heater indication
3: Cooler indication
4: Batteries weak
5: If lit-up 6 displays the measured temperature
6: Measured temperature or set temperature
7: Moving bars when transmitting a radio signal
Or Title for installation Parameters (rF, J0,CLr…)
DISPLA
Y
Press the OK key during 5 seconds, Then use + or - keys to select the installation parameter to be adjusted.
Press OK to toggle the parameter setting or edit the value. If the value starts to blink you can use + / - keys to adjust this
value. Press + & - keys at the same time to reset this value to the factory default value. Once you have adjusted the
value press OK to validate this parameter value.
When you have finished, use + / - keys to go to ‘rF’ display and then press OK key to exit installation parameter menu.
rF : Radio configuration mode (see section). Press OK to return to normal operation modes.
J0 : °C
/ °F temperature display selection
J1 : “Hot”
/ “Cold” regulation mode. Select Hot for a Heater system, select Cold for a Cooling system
Cy : Proportional Integral regulation time cycle value in minutes (default: 15 minutes cycle)
bp : Proportional Integral regulation band amplitude value in degrees °C/°F (default: 2.0°C
/3.6°F)
J5 : Select “PMP” to perform an 1 minute exercise everyday (if installation inactive during a day)
J6 : Air or Floor temperature regulation selection. (if no Floor sensor, regulation will use Air sensor)
J7 : “rEG” (Proportional Integral) or “HYs” (0.3°K Hysteresis) regulation type selection
Cp : compensation value in °C/°F (default: 2.0°C
/3.6°F) this parameter must be adjusted by a professional.
Ao : Air sensor offset adjustment (default: no offset). Display measured Air sensor value
Fo : Floor sensor offset adjustment (default: no offset). Display measured Floor sensor value
FL : Floor temperature LOW limitation (default: 5°C
/41°F), effective only if floor sensor present
FH : Floor temperature HIGH limitation (default: 28°C/82°F) , effective only if floor sensor present
CLr : Press OK key during 5s to reset all the WFHT LCD parameters to factory defaults
* (Default parameters are underlined.)
INSTALLATION PARAMETERS MENUS
Optional external sensor 10K
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Watts WFHTRF 010 -20433 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Watts WFHTRF 010 -20433 in the language / languages: English, Spanish as an attachment in your email.

The manual is 4,06 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Watts WFHTRF 010 -20433

Watts WFHTRF 010 -20433 User Manual - English - 4 pages

Watts WFHTRF 010 -20433 User Manual - English - 4 pages

Watts WFHTRF 010 -20433 User Manual - English - 2 pages

Watts WFHTRF 010 -20433 User Manual - German - 4 pages

Watts WFHTRF 010 -20433 User Manual - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info