805520
2
Zoom out
Zoom in
Previous page
1/4
Next page
Parameters
Installer’s Advanced Menu
number
names
Description of the parameter
Factory value
Other possibility
10
LanG
Selection the language for the both parameters menus.
GB
English
Fr
French
11
Air.S
View of the measured values of the ambient sensor.
__._
12
OUT.S
View of the measured values of the floor (external)
sensor.
__._
13
FL.Lo
Lower limit of the floor temperature.
no
The lower
limitation is not
used
From 5°C to FL.Hi
14
FL.Hi
Upper limit of the floor temperature.
no
The upper
limitation is not
used
From FL.Lo to 37°C
15
regu
Selection of regulation type
pwm
Proportional
band (PWM)
hys
0,5°C Hysteresis (On/Off)
16
t.Cy
Selection of the proportional band duration in minutes
(cycle duration)
10
Ideal value for
all Electrical
floors heating
application.
You could increase this
value if the thermostat is
used for other heating
application (Oil Boiler...)
17
t.on
Minimal starting time in minutes
002
Adjustable 0 to T cy/2
18
t.off
Minimal resting time between 2 heating cycles in minutes
002
Adjustable 0 to T cy/2
19
Pwm.v
Value of the proportional band in °C
Note:
If the value of proportional band is too big the system
reactivity will be slower and could affect the steps of the
program.
3.0
Ideal value for
all Electrical
floors heating
application.
Adjustable 1 to 6.0
A well insulated house
« 1.5°
A not insulated house
« 4°C »
20
Cp
Compensating value of the regulation
This value will need to be modified only if the thermostat
is perturbed by the heating element.
Generally never the case with electrical floor heating.
00.0
Adjustable 0 to
14.0
Increase this value if the
thermostat is too close to
the heating source.
21
Clr EEp
All parameters will be reloaded with the factory value.
Press on the (OK) key during few seconds.
22
End
To exit the installer‟s menu
Press on the (OK) to exit.
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Watts Wattstemp 850 - 860 - Flush mounting thermostat series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Watts Wattstemp 850 - 860 - Flush mounting thermostat series in the language / languages: English, French as an attachment in your email.

The manual is 0.41 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info