2.Quick Start
13
will last about a few hundred milliseconds, and the data acquired in this period will
be marked as "invalid".
When the dual display is enabled, only the reading of main display function can be
saved.
Troubleshooting
1. The instrument is powered on but no Display.
1) Check if the power is connected properly.
2) Check if the line fuse which is below the AC Mains Input is used appropriately and
in good condition (see page 15, Appendix C: Line Fuse Replacement).
3) Restart the instrument after the steps above.
4) If the problem still exists, please contact us for our service.
2. The reading does not change when a current signal is input.
1) Check whether the test lead is correctly inserted into the current input terminals
(I terminal and LO Input terminal).
2) Check whether the current terminal fuse at the front panel is burned out.
Please refer to "7 Current Terminal Fuse" in "Front panel overview" on page 7.
3) Check whether the DCI or ACI measurement function is enabled.
4) Check whether the DCI measurement function is used to measure AC current.
If you encounter other problems, try to reset the settings or restart the instrument. If it
still cannot work properly, please contact us for our service, and provide your device
information (press the front panel key to view it).
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Voltcraft VC-7055BT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Voltcraft VC-7055BT in the language / languages: English as an attachment in your email.

The manual is 5,09 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Voltcraft VC-7055BT

Voltcraft VC-7055BT User Manual - German - 19 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info