Before initial use you should test the device on your lower arm.
If there is no undesired skin reaction, you can use the device
on your face.
When using the device a tingling sensation and a skin redden-
ing is normal and should disappear within half an hour.
In order to avoid the formation of blotches, during the ap-
plication the attachment should be kept in constant motion
on the skin. You are recommended to stretch the skin on the
cheeks, for example, to avoid excessive suction.
Without pressing against the skin you move the device slowly
along a straight line, and not in circles!
PLEASE NOTE! If the device stops or cannot be switched on, the
battery needs charging.
While the device is running, the suction head is lit blue. The blue
light has an additional purifying function during acne treatment.
Three attachments are supplied:
Round pore attachment for cleaning the pores, not suitable
for the skin around the eyes
Oval attachment for stimulating the circulation of the skin
Microcrystalline attachment for microdermabrasion: removal
of dead skin cells by friction and suction of the face, elbows,
knees etc.
Cleaning Pores
1. Remove make-up and clean your face in the usual way.
2. For optimum results, the pores should be opened before the
application. For this purpose you soak a small, clean annel in
hot water, wring it out and place it on your face. As an alterna-
tive you can carefully place your face above a dish with hot
water, or use the device immediately after a shower or bath.
3. Next you pat your face dry.
4. Place the round pore attachment on the suction head.
5. Press the on / off button. The device switches on.
6. In order to remove sebum and blackheads, you place the at-
tachment against the skin (without pressure) and slowly move
it outwards from the centre in straight lines across the skin. Do
not move it backwards and forwards along the same line. Re-
peat if necessary. Any acne spots should be vacuumed brie y
before the attachment is removed again. Do not move side-
ways!
7. After the application you switch off the device, remove the at-
tachment and clean it.
8. Soak a cotton pad with facial lotion or the like and clean your
face. After that you apply a skin care product.
Microdermabrasion
1. Remove make-up and clean your face in the usual way. Then
dry it thoroughly.
2. Place the microcrystalline attachment on the suction head.
3. Press the on / off button. The device switches on.
4. Begin the facial treatment on the chin and proceed to the
forehead. Move the attachment slowly without pressure over
the skin. Move it outwards from the centre in straight lines.
Do not move it backwards and forwards along the same line.
NOTE: the microcrystalline attachment can be used on parts of
the body such as the elbows or knees.
5. After the application you switch off the device, remove the at-
tachment and clean it.
6. Apply a skin care product.
Stimulating the circulation of the skin
1. Remove make-up and clean your face in the usual way. Then
dry it thoroughly.
2. Place the oval attachment on the suction head.
3. Press the on / off button. The device switches on.
4. Any areas where wrinkles form (e.g. around the mouth) should
be vacuumed brie y before the attachment is removed again.
Do not repeat too often in one location – this could lead to
blotches!
5. After the application you switch off the device, remove the at-
tachment and clean it.
6. Apply a skin care product.
Cleaning and Care
NOTE
Do not use any corrosive or abrasive cleaning agents!
After every use the attachments should be cleaned under run-
ning water. If necessary you can use a mild detergent and cot-
ton buds.
Wipe down the device with a damp cloth if necessary and then
dry it with a soft cloth.
Store the appliance away from dust and direct sunlight in a dry,
clean place that is not accessible to children and animals.
If the attachments do not cling to the suction head, the silicone
ring is probably damaged and must be replaced. Replacement
silicone rings are supplied.
• If the lter in the suction head is dirty, it should be replaced (see
below). Replacement lters are supplied.
Changing the lter
1. Pull the round silicone insert out of the suction head.
2. Use a sharp object (e.g. needle, tweezers) to remove the dirty
lter from the suction head.
3. Separate a fresh lter from the foil and place it into the suction
head.
4. Put the round silicone insert back into the suction head.
Technical Data
Article number: 04159
Model number: BZ-0708
Operating time: approx. 3 5 hours (when fully charged)
Charging time: 3 5 hours (with 5 V DC; 1 A)
Operating voltage: 3.7 V DC; (Li-polymer battery, 900 mAh)
Charging voltage/current: 5 V DC; 1 A
Power: max. 5 W
Light wavelength: 465 nm
Disposal
Dispose of the packaging in an environmentally
friendly manner and take it to a recycling centre.
Dispose of the device with the integrated battery at
a recycling centre for used electrical and electronic
devices, and not in the household waste. For more
information, contact your local authorities.
Article number: 04159
Z 04159 M DS V1 1017
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vitalmaxx BZ-0708 - Z04159 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vitalmaxx BZ-0708 - Z04159 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 0,41 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info