580332
72
Zoom out
Zoom in
Previous page
1/74
Next page
APPENDICES
D-304829 PowerMaster-10/30 G2 User's Guide 71
Message to Private
Phones
Tone Tone or voice
Ring Detection The unit does not support ring detection without
DC voltage present on the telephone lines.
The unit does not support ring detection without
DC voltage present on the telephone lines
E5. Physical Properties
PowerMaster-10 G2 PowerMaster-30 G2
Operating Temp.
Range
14°F to 120°F (-10°C to 49°C)
Note: For UL Listed product, the ambient
temperature is 32°F to 120°F (0°C to 49°C)
14°F to 120°F (-10°C to 49°C)
Note: For UL Listed product, the ambient
temperature is 32°F to 120°F (0°C to 49°C)
Storage Temp.
Range
-4°F to 140°F (-2C to 60°C) -4°F to 140°F (-20°C to 60°C)
Humidity 93% relative humidity, @ 30°C (86°F) 93% relative humidity, @ 30°C (86°F)
Size 196 x 180 x 55 mm (7-5/8 x 7 x 2 in.) 266 x 201 x 63 mm (10-7/16 x 7-7/8 x 2-1/2 in.)
Weight 658g (23 Oz) (with battery) 1.44Kg (3.2 pounds) (with battery)
Color White White
E6. Peripherals and Accessory Devices
PowerMaster-10 G2 PowerMaster-30 G2
Modules GSM/GPRS, IP (future use) GSM/GPRS, IP (future use)
Additional
wireless devices
30 detectors, 8 keyfobs, 8 keypads, 4 sirens,
4 repeaters, 8 proximity tags
64 detectors, 32 keyfobs, 32 keypads (10 KP-
250 PG2), 8 sirens, 4 repeaters , 32 proximity
tags
Wireless Devices
and peripherals
Magnetic Contact: MC-302 PG2, MC-302E
PG2, MC-302EL PG2, MC-302V PG2
Motion Detectors: Next PG2; Next K9 PG2,
TOWER-20 PG2, TOWER-32AM PG2 (not UL
listed), TOWER-32AM K9 PG2 (not UL listed),
TOWER-30AM PG2, TOWER-30AM K9 PG2,
CLIP PG2 (not UL listed), TOWER CAM PG2
PIR Camera Detectors: Next CAM PG2;
Next CAM-K9 PG2
Smoke Detector: SMD-426 PG2, SMD-427
PG2
GSM Module: GSM-350 PG2
(optional)
Keyfob: KF-234 PG2, KF-235 PG2 (not UL
listed)
Keypad: KP-140 PG2/KP-141 PG2 (with
proximity tag), KP-160 PG2, KP-250 PG2
1
Indoor Siren: SR-720 PG2, SR-720B PG2
Outdoor Sirens: SR-730 PG2, SR-740 PG2,
SR-740 HEX PG2
Repeater: RP-600 PG2
Gas: GSD-441 PG2 (not UL listed), GSD-442
PG2
Glass-break: GB-501 PG2 (not UL listed)
Temperature: TMD-560 PG2 (not UL listed)
Flood: FLD-550 PG2 (not UL listed)
Shock: SD-304 PG2 (not UL listed)
Note: UL requires that when using remote
smoke/CO detectors and repeaters, each
detector must be within range (STRONG) of 2
repeaters at all times (for path redundancy –
UL 985).
Magnetic Contact: MC-302 PG2, MC-302E
PG2, MC-302EL PG2, MC-302V PG2
Motion Detectors: Next PG2; Next K9 PG2,
TOWER-20 PG2, TOWER-32AM PG2 (not UL
listed), TOWER-32AM K9 PG2 (not UL listed),
TOWER-30AM PG2, TOWER-30AM K9 PG2,
CLIP PG2 (not UL listed), TOWER CAM PG2
PIR Camera Detectors: Next CAM PG2;
Next CAM-K9 PG2
Smoke Detector: SMD-426 PG2, SMD-427
PG2
GSM Module: GSM-350 PG2
(optional)
Keyfob: KF-234 PG2, KF-235 PG2 (not UL
listed)
Keypad: KP-140 PG2/KP-141 PG2 (with
proximity tag), KP-160 PG2, KP-250 PG2
1
Indoor Siren: SR-720 PG2, SR-720B PG2
Outdoor Sirens: SR-730 PG2, SR-740 PG2,
SR-740 HEX PG2
Repeater: RP-600 PG2
Gas: GSD-441 PG2 (not UL listed), GSD-442
PG2
Glass-break: GB-501 PG2 (not UL listed)
Temperature: TMD-560 PG2 (not UL listed)
Flood: FLD-550 PG2 (not UL listed)
Shock: SD-304 PG2 (not UL listed)
Note: UL requires that when using remote
smoke/CO detectors and repeaters, each
detector must be within range (STRONG) of 2
repeaters at all times (for path redundancy –
UL 985).
1
KP-250 PG2 is not relevant for UL installations
72


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Visonic PowerMaster-10-30 G2 Version 18 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Visonic PowerMaster-10-30 G2 Version 18 in the language / languages: English as an attachment in your email.

The manual is 2,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Visonic PowerMaster-10-30 G2 Version 18

Visonic PowerMaster-10-30 G2 Version 18 Installation Guide - Dutch - 112 pages

Visonic PowerMaster-10-30 G2 Version 18 User Manual - Dutch - 72 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info