Cause Remedy
The solar control unit MCB has responded. Inform your local heating contractor.
Power failure The solar control unit automatically returns to operation
once the power supply has been restored.
The power distribution MCB (main domestic MCB) has
responded.
Check the MCB and inform your heating contractor if
necessary.
The collector limit temperature or maximum cylinder
temperature has been reached.
Wait until the relevant temperature has fallen below its
respective limit.
The solar control unit is in manual mode.
The display shows "Æ" and "¨" flashes.
Select "Auto":
1. Press until "ANL" is displayed.
2. Press until "HND 1" or "HND 2" is displayed.
3. Press OK, "SET" flashes.
4. Press until "Auto" is displayed.
5. Press OK to confirm.
6. Press . The collector temperature is displayed.
There is no DHW available
Cause Remedy
The solar control unit is faulty. Inform your local heating contractor.
The collector temperature is too high, safety shutdown
by the solar control unit.
Wait until the collector temperature has dropped.
The set cylinder temperature (set DHW temperature) is
set too low.
Inform your local heating contractor.
The solar circuit pump is faulty. Inform your local heating contractor.
The DHW cylinder is not being reheated:
The operating and time programs on the boiler control
unit are incorrectly set.
Enable DHW heating.
Operating instructions of the boiler control unit
The display is flashing
Cause Remedy
Example, sensor fault
KOL
°C
The sensor symbol in the system scheme flashes
quickly.
¨ flashes.
Read off the fault code. Inform your local heating con-
tractor.
In the example, the collector temperature sensor has a
short circuit.
88.8 Sensor short circuit
888.8 Sensor lead break
Note
Check other sensors with / .
What to do if...
The solar thermal system does not start
5592640
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Viessmann VITOSOLIC 100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Viessmann VITOSOLIC 100 in the language / languages: English as an attachment in your email.

The manual is 0.34 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Viessmann VITOSOLIC 100

Viessmann VITOSOLIC 100 User Manual - German - 12 pages

Viessmann VITOSOLIC 100 Installation Guide - Dutch - 72 pages

Viessmann VITOSOLIC 100 User Manual - Dutch - 8 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info