652056
5
Zoom out
Zoom in
Previous page
1/8
Next page
5
blau mit roter Markierung
blau mit grüner Markierung
gelb + Widerstand / Markierung
gelb
braun (+Diode bei LED-Licht)
rot
rot
Signal Hp0 (Halt)
Signal Hp1; zweiflügliges Signal Hp2 (Fahrt/Langsamfahrt)
gemeinsamer Mittelpunkt der Antriebsspulen
Licht
Licht (Masse)
Kontakt für Zugbeeinflussung
Kontakt für Zugbeeinflussung
blue with red marking
blue with green marking
yellow with resistor or marker
yellow
brown (+diode for LED lighting)
red
red
Signal Hp0 (Stop)
Signal Hp1; signal with two arms Hp2 (Proceed/Proceed slowly)
common pole for the drive coils
Light
Light (ground)
contact for train control
Contact for train control
Fig. 5
Abb. 5
4. Befestigen Sie das Signal mit dem beilie-
genden Befestigungsring. Führen Sie dazu alle
Kabel des Signals durch den Ring. Die Federn
des Rings müssen in Richtung des Signals zei-
gen (Abb. 4). Halten Sie das Signal am Sockel
fest. Schieben Sie den Ring über den Antrieb
und drücken Sie ihn gegen die Modellbahnplat-
te. Drehen Sie den Ring um 90°, um ihn zu ar-
retieren.
5. Anschluss
Vorsicht:
Alle Anschluss- und Montagearbeiten nur bei
abgeschalteter Betriebsspannung durchführen!
Ausschließlich nach VDE / EN-gefertigte
Modellbahntransformatoren verwenden!
Stromquellen unbedingt so absichern, dass es
bei einem Kurzschluss nicht zum Kabelbrand
kommen kann.
Widerstand und Diode an den Enden der
Anschlussdrähte sind für die Funktion erforder-
lich. Keinesfalls entfernen! Widerstände nicht
mit Isolationsmaterial umhüllen, da sonst keine
ausreichende Kühlung möglich ist!
Die Betriebsspannung beträgt 16 V = / ~.
Schließen Sie das Signal gemäß den Abb.en 6
oder 7 an. Zur Bedeutung der Kabelfarben siehe
Abb. 5.
Für die Versorgung der Signalbeleuchtung emp-
fehlen wir einen separaten Transformator. Das
verhindert ein eventuelles Flackern der Beleuch-
tung beim Umschalten des Signales durch den er-
höhten Strombedarf des Antriebes.
Gleichstrombetrieb: Schließen Sie die beiden
gelben Kabel an den Minuspol des Trafos an.
the drive unit of the signal (g. 4). Turn the ring
90° to arret it.
5. Connection
Caution:
Make sure that the power supply is switched
off when you mount the device and connect
the wires!
Only use VDE/EN tested special model train
transformers for the power supply!
The power sources must be protected to pre-
vent the risk of burning wires.
Resistor and diode at the cables are needed
for proper function of the lamp. Never cut them
off! Never cover resistor or diode with insula-
tion material, because they have to be cooled
by surrounding air!
The operating voltage is 16 V =/~.
Now make the electrical connection as per g. 6
or 7. For the meaning of the cable colours refer
to g. 5
As a supply for the signal light, we recommend a
separate transformer. This will prevent ickering of
the lights due to high consumption of the drive.
Connect the signal light to the transformer via the
yellow cable with black marking and the brown ca-
ble with the diode.
Direct current: Connect both yellow cables to the
negative pole of the transfomer.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Viessmann 4501 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Viessmann 4501 in the language / languages: English, German as an attachment in your email.

The manual is 1,25 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Viessmann 4501

Viessmann 4501 User Manual - Dutch, French - 8 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info