3.2 Generic features
Below features apply to all types of systems, and all types of batteries. Both lead batteries and
batteries with a CAN-bus BMS.
Add a user-configurable maximum charge current setting. This is available in the Venus GUI
(Settings → System Setup) and works across the whole system. MPPTs are automatically
prioritized over the mains. In case a CANBUS-BMS is connected and the BMS requests a
maximum charge current that is different from the user-configurable setting, the lower of the
two will be used.
Add shared voltage sense (SVS) for VE.Bus devices and VE.Direct Solar Chargers.
The system automatically selects the best available voltage measurement. It will use the
voltage from the BMS or a BMV battery monitor, if possible, otherwise it will use the
battery voltage reported by the VE.Bus system.
The voltage displayed on the GUI reflects the same voltage measurement.
Shared Voltage Sense (SVS) is by default enabled when DVCC is enabled. It can be
disabled with a switch in the Settings → System Setup menu.
3.3 Features for systems using a CAN-bus BMS systems
These features apply to all types of systems (ESS and not ESS), that have a CAN-bus BMS connected
battery.
CAN-bus BMS control is no longer tied into ESS. It now works for other systems as well, including
Off-grid and plain backup systems. It is not longer necessary to wire allow-to-charge and allow-
to-discharge connections to the AUX inputs on a Multi or a Quattro.
VE.Direct MPPT Solar Chargers are now also controlled with the max charge current, just like
Multis and Quattros already were.
When inverting, ie in Island mode, Multis and Quattros will shut down when the max discharge
current is zero. They will automatically start again as soon as either AC mains returns, or when
BMS increases the max discharge current again.
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron Color Control GX at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron Color Control GX in the language / languages: English as an attachment in your email.

The manual is 0.97 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info