785221
1
Zoom out
Zoom in
Previous page
1/5
Next page
Victron Energy bv / De Paal 35 / 1351 JG ALMERE / The Netherlands
Phone: (+31) (0)36 535 97 00 / www.victronenergy.com / e-mail: sales@victronenergy.com
BMS12/200
ENGLISH
1. Mount the BMS preferably on a vertical surface, for optimal
cooling.
2. Determine the rating of fuse AB (see figure and table 1).
The fuse on input AB doubles as a shunt. The BMS will limit the
input current according to the rating of this fuse. For fuse ratings
and corresponding current limit please see table 1.
Choosing the right fuse will prevent overheating of the alternator
and/or DC cabling.
3. Determine the rating of fuse LB (see figure).
This fuse should be rated in accordance with the expected load
current and the cross section of the cabling to the load.
4. Disconnect the cabling from the plus pole of the starter battery.
5. Pull off the REMOTE on/off connector to prevent unwanted
switching of the BMS.
6. Install and connect all electrical cabling and fuses AB, LB, but
leave the plus poles of the Li-ion batteries and starter battery
disconnected.
7. Daisy-chain the battery control cables between the Li-ion batteries
and connect to the BMS.
8. Connect the plus cabling to the Li-ion batteries and the starter
battery.
9. Reinsert the REMOTE on/off connector on the BMS.
The BMS is now ready for use.
Notes:
a) A battery charger can be connected to input AB instead of the
alternator.
b) The Li-ion batteries can be charged as well as discharged through
input/output LB.
c) When a load with a large electrolytic capacitor bank (such as an
inverter or inverter/charger rated at 1200VA or more) is connected
to LB, the BMS will limit its average output current during start-up
to approximately 80A. Therefore the capacity to simultaneously
start-up other DC loads is limited to 80A. Once the capacitor bank
is fully charged, the current limit increases to 400A.
BMS 12/200 specification
Maximum number of 12,8V batteries
10
Maximum charge current, Power Port AB
80A @ 40°C
Maximum charge current, Power Port LB
200A @ 40°C
Maximum continuous discharge current, LB
200A @ 40°C
Peak discharge current, LB (short circuit proof)
400A
Approximate cut-off voltage
11V
GENERAL
No load current when operating
10mA
Current consumption when switched off
5mA
Current consumption after battery discharge
cut-off due to low cell voltage
3mA
Operating temperature range
-40 to +60°C
Humidity, maximum
100%
Humidity, average
95%
Protection, electronics
IP65
DC connection AB, LB and battery minus
M8
DC connection battery plus
Faston female
6.3 mm
LED’s
Battery being charged through Power Port AB
green
Battery being charged through Power Port LB
green
Power port LB active
green
Over temperature
red
ENCLOSURE
Weight (kg)
1.8
Dimensions (hxwxd in mm)
65 x 120 x 260
STANDARDS
Emission
EN 50081-1
Immunity
EN 50082-1
Automotive Directive
2004/104/EC
Revision : Rev 04
Date : 18-05-2020
Table 1
(input AB) is less than 40 A,
please use this ATO fuse holder
Fuse AB Max. charge current
100 A
90 A
80 A
70 A
60 A
40 A
2 x 30 A 35 A
2 x 20 A 25 A
2 x 15 A
20 A
2 x 10 A
18 A
2 x 7.5 A
12 A
1


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron BMS 12-200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron BMS 12-200 in the language / languages: English, German, Dutch, French, Spanish as an attachment in your email.

The manual is 2.1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info