Battery Voltage12/24V with automatic system voltage detection*
Rated charge current5 A10 A20 A30 A
Recommended solar array
36 cell for 12 V / 72 cell for 24 V
Automatic low voltage load
disconnectYes
Maximum solar voltage28 V for a 12 V system and 55 V for a 24 V system(1)
Self-consumption< 10 mA
Overload protection
Shut down after 60 s in case of 130% load
Shut down after 5 s in case of 160% load
Short circuit: immediate shut down
GroundingCommon positive
Operating temp. range-20 to +50°C (full load)
Humidity (non condensing) Max 95 %
Settings
Charge voltage 'absorption'14.2 V / 28,4 V
Charge voltage 'float'13.8 V / 27,6 V
Load disconnect11,2V / 22,4V
Load reconnect12,6V / 25,2V (manual)
13,1V / 26,2V (automatic)
Enclosure
Protection classIP20
Terminal size5 mm² / AWG10
Weight0,13 kg0,15 kg
Dimension (h x w x d)70 x 133 x 33,5 mm (2.8 x 5.3 x 1.3 inch)
MountingVertical wall mount Indoor only
Humidity (non condensing) Max. 95%
Operating temperature-20°C to +50°C (full load)
CoolingNatural convection
Standards
SafetyIEC 62109-1
EMCEN61000-6-1, EN61000-6-3, ISO 7637-2
1) For 12V use 36 cell solar panels
For 24V use 72 cell solar panels
or 2x 36 cell in series
2) The controller switches to the lower float
voltage level 2 hours after the absorption voltage
has been reached.
Whenever the battery voltage becomes lower
than 13 V, a new charge cycle is triggered.
0 Load output permanently off9
Load output turned on during 9
hours after sunset
1
Load output turnedon during 1
hour after sunset
10
Load output turned on during 10
hours after sunset
2
Load output turned on during 2
hours after sunset
11
Load output turned on during 11
hours after sunset
3
Load output turned on during 3
hours after sunset
12
Load output turned on during 12
hours after sunset
4
Load output turned on during 4
hours after sunset
13
Load output turned on during 13
hours after sunset
5
Load output turned on during 5
hour after sunset
H Manual load control
6
Load output turned on during 6
hours after sunset
C
Load output controlled by battery
voltage only
7
Load output turned on during 7
hours after sunset
L Dusk to dawn mode
8
Load output turned on during 8
hours after sunset
d Debug mode
IMPORTANT
•Always connect the batteries first, in order to allow the
Controller to recognize system voltage
•Use a 12V (36 cells) solar array for a 12V battery system.
•Use a 24V (72 cells) solar array for a 24V battery system.
Need help? Post your question in this forum.
Report abuse
Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.
Product:
Forumrules
To achieve meaningful questions, we apply the following rules:
First, read the manual;
Check if your question has been asked previously;
Try to ask your question as clearly as possible;
Did you already try to solve the problem? Please mention this;
Is your problem solved by a visitor then let him/her know in this forum;
To give a response to a question or answer, do not use this form but click on the button 'reply to this question';
Your question will be posted here and emailed to our subscribers. Therefore, avoid filling in personal details.
Register
Register getting emails for Victron BlueSolar PWM-Light 12 24V-30A at:
new questions and answers
new manuals
You will receive an email to register for one or both of the options.
Get your user manual by e-mail
Enter your email address to receive the manual of Victron BlueSolar PWM-Light 12 24V-30A in the language / languages: English as an attachment in your email.
The manual is 0.09 mb in size.
You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.
The manual is sent by email. Check your email
If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.
The email address you have provided is not correct.
Please check the email address and correct it.
Your question is posted on this page
Would you like to receive an email when new answers and questions are posted? Please enter your email address.