574297
2
Zoom out
Zoom in
Previous page
1/2
Next page
mOn
(
mOnitOr
)
Press(or Pressand hold)the assigned
PF
key momentarilyto dis-
abletheTone squelch.When disables theTonesquelch, the LED
indicatoronthetopoftheradiowillglowgreen.
SQl Off
Press(orPressandhold)theassigned
PF
keytodisabletheNoise
andTonesquelch.Againpress(orPressandhold)theassigned
PF
keytoresumenormal(quiet)NoiseandTonesquelchaction.
SQl Set
Youcanmanuallyadjustthesquelchlevelusingthisfunction.Press
the assigned
PF
key to toggle the squelch threshold level “High”
and“Low”.
lOw POwer
Press(orPressandhold)theassigned
PF
keytosettheradio’s
transmitterto the “Low Power” mode, thus extending battery
life.Press(orPressandhold)theassigned
PF
keyagaintoreturn
to“HighPower”operationwhenindifcultterrain.Whenthera-
dio’stransmitterissetto“LowPower”mode,theLEDindicator
onthetopoftheradiowillglowgreen.
Scan
The Scanning feature isused tomonitor multiplechannels pro-
grammedintothe transceiver.Whilescanning,theradiowillcheck
eachchannelforthepresenceofasignal,andwillstoponachannel
ifasignalispresent.
Toactivatescanning:
Press(orPressandhold)theassigned
PF
key.
The scanner will search the channels, looking for activeones;
it willpause each timeit nds achannelon whichsomeoneis
speaking. Whenthescanneris activated, the LED indicator on
thetopoftheradiowillglowgreen.
Tostopscanning:
Press(orPressandhold)theassigned
PF
key.
Operationwillreverttothechanneltowhichthe
CH
knobisset.
KeY functiOnS
fOllOw-me Scan
“Follow-Me”ScanfeaturechecksaUser-assignedPriorityChannel
regularlyasyouscantheotherchannels.Thus,ifonlyChannels1,
3,and5(ofthe8availablechannels)aredesignatedfor“Scanning,”
theusermaynonethelessanychannelasthe“User-assigned”Prior-
ityChannelviathe“Follow-Me”feature.
Press theassigned
PF
keyto activate “Follow-Me”scanning,then
turn the
CH
selector knob to the channel which you wanttodes-
ignate as the“User-Assigned PriorityChannel”.When the scanner
stopsonan“active”channel,theUser-assignedPriorityChannelwill
automatically bechecked every fewseconds (interval programmed
byyourDealer).
Scan Set
Press(orpressandhold)theassigned
PF
keytodeletetheCurrent
MemoryChannelfromtheScanningList.Whenyoudeleteachan-
nelfromtheScanningList,alowtonebeepwillsound.Torestorea
particular channelto your Scanning List,press (or press andhold)
theassigned
PF
keyagain;ahightonebeepwillsound.
dw
(
dual watch
)
The Dual Watch feature is similar to the Scan feature, except that
onlytwochannelsaremonitored:thecurrentoperatingchannel,and
the“Priority”channel.
ToactivateDualWatch:
Press(orPressandhold)theassigned
PF
key.
Thescannerwillsearchthetwochannels;itwillpauseeachtime
itndsachannelonwhichsomeoneisspeaking.WhentheDual
Watchfeature is activated,the LED indicatoron the topof the
radiowillglowgreen.
TostopDualWatch:
Press(orPressandhold)theassigned
PF
key.
Operationwillreverttothechanneltowhichthe
CH
knobisset.
ta Scan
PresstheassignedprogrammablekeytotoggletheTA(TalkAround)
scanfeature“On”and“Off.”
WhileTAscanisproceeding,the
VX-230
willsearchboththetrans-
mitandreceivefrequencies(andtheLEDindicatoronthetopofthe
radiowillglowgreen).Whenasignalisencounteredonthereceive
frequency,the
VX-230
willpauseuntilthesignaldisappears.
Whenasignalisencounteredonthetransmitfrequency,the
VX-230
willcheckforactivityonthereceivefrequencyeveryfewseconds
(intervalprogrammedbyyourDealer).
ta
(
talk arOund
)
Press (orPress and hold) theassigned
PF
keyto activate theTalk
Aroundfeaturewhenyou areoperatingon duplexchannelsystems
(separate receive and transmitfrequencies,utilizinga“repeater”
station).TheTalkAroundfeatureallowsyoutobypasstherepeater
stationandtalkdirectlytoastationthatisnearby.Thisfeaturehas
noeffectwhenyouareoperatingon“Simplex”channels,wherethe
receiveandtransmitfrequenciesarealreadythesame.
Whenthe“TA”functionis activated,the LEDindicatoronthetop
oftheradiowillglowgreen.
tX Save diSaBle
Press(orPressandhold)theassigned
PF
keytodisabletheTransmit
BatterySaver,ifyouareoperatinginalocationwherehighpoweris
almostalwaysneeded.
The Transmit BatterySaver helps extend battery lifeby reducing
transmitpowerwhenaverystrongsignalfromanapparentlynearby
station is being received.Undersome circumstances, though, your
hand-heldradiomaynotbeheardwellattheotherendofthecom-
municationpath,andhighpowermaybenecessaryatalltimes.
reSet
Press(orPressandhold)theassigned
PF
keytosilencethereceiver
andresetforanothercall,whenacommunicationisnished.
call
Press(orPressandhold)theassigned
PF
keytosendaprogrammed
2-or5-Tonesequentialtone.
artS
(
autO range tranSpOnd SYStem
)
Thissystemisdesignedtoinformyouwhenyouandanother
ARTS
-
equippedstationarewithincommunicationrange.
During
ARTS
operation,your radio automatically transmits for
about1secondevery55secondsinanattempttoshakehandswith
theotherstation.
Ifyouareoutofrangeformorethantwominutes,yourradiosenses
thatnosignalhasbeenreceived,aringingbeeperwillsound.Ifyou
subsequently move backinto range, as soonas theother station
transmits,yourbeeperwillsound.
call 2, call 3
Press(orPressandhold)theassigned
PF
keytosenda5-Tonese-
quentialtonegroupwhichispre-dened.
SPeed dial
YourDealermayhaveapre-programmedAuto-Dialtelephonenum-
bermemoryintoyourradio.Press(orPressandhold)theassigned
PF
key to send the pre-programmedAuto-Dial telephonenumber.
TheDTMFtonessentduringthedialingsequence willbe heardin
thespeaker.
lOck
Press(orPressandhold)theassigned
PF
keytolockthe
CH
knob,
PF
keys,and
PTT
switch.Thepreciselockoutcongurationispro-
grammedbyyour
VERTEX STANDARD
dealer.
emergency
The
VX-230
series includesan“Emergency” feature, whichmay
be useful,ifyou have someonemonitoringon the samefrequency
asyourtransceiver’schannel.Forfurtherdetailscontactyour
VER-
TEX STANDARD
dealer.
lOne wOrker
Pressandholdtheassigned
PF
keytotoggletheLoneWorkerfea-
ture“ON”and“OFF.”
TheLoneWorkerfeaturewillemitanaudiblealarmfor30seconds
at one second intervals when the LoneWorkerTimerhasexpired.
Iftheuserdoesnotresetthetimerbypressingthe
PTT
switch,the
radioswitchestotheEmergencymode.
Declaration of Conformity
We, YAESU UK Ltd. declare under our sole responsibility that the
following equipment complies with the essential requirements of
the Directive 1999/5/EC.
Type of Equipment: FM Transceiver
Brand Name: VERTEX STANDARD
Model Number: VX-231-D0-5 / VX-231-G6-5
Manufacturer: Vertex Standard Co., Ltd.
Address of Manufacturer: 4-8-8 Nakameguro Meguro-Ku, Tokyo
153-8644, Japan
Applicable Standards:
This equipment is tested and conforms to the essential require-
ments of directive, as included in following standards.
EN 300 086-2 V1.3.1
Radio Standard:
EN 301 489-01 V1.8.1
EMC Standard: EN 301 489-05 V1.3.1
EN 60950-1: 2006 +A11: 2009 +A1: 2010
Safety Standard:
The technical documentation as required by the Conformity As-
sessment procedures is kept at the following address:
Company: YAESU UK Ltd.
Address: Unit 12, Sun Valley Business Park, Winnall Close
Winchester, Hampshire, SO23 0LB, U.K.
attentiOn in Case OF use
This transceiverworks on frequencieswhich are notgener-
allypermitted.
For frequency allocation,
apply for a licence at your
localspectrummanagement
authority.
For actualusage contact
yourdealerorsalesshopinordertogetyourtransceiverad-
justedtotheallocatedfrequencyrange.
nOtiCe !
There are noowner-serviceable parts inside the transceiver.
AllservicejobsmustbereferredtoanauthorizedVERTEX
STANDARD ServiceRepresentative.Consult yourAutho-
rizedVERTEX STANDARD Dealer for installation of op-
tionalaccessories.
DispOsal OF yOur eleCtrOniC anD
eleCtriC equipment
Products with thesymbol (crossed-outwheeled
bin)cannotbedisposedashouseholdwaste.
Electronicand Electric Equipmentshould be re-
cycledatafacilitycapableofhandlingtheseitems
andtheirwastebyproducts.
In EU countries, please contact yourlocal equipment sup-
plierrepresentative or service centerfor information about
thewastecollectionsysteminyourcountry.
impOrtant nOtiCe FOr nOrth ameriCan users
regarDing 406 mhz guarD BanD
TheU.S. CoastGuard andNational Oceanographic andAt-
mosphericAdministrationhaverequested the cooperation of
theU.S.FederalCommunicationsCommissioninpreserving
theintegrityoftheprotectedfrequencyrange406.0to406.1
MHz,whichisreserved foruseby distressbeacons.Donot
attemptto programthisapparatus,underany circumstances,
foroperationinthefrequencyrange406.0-406.1MHzifthe
apparatusistobeusedinornearNorthAmerica.
Warning - Frequency band 406 - 406.1 MHz is reserved
for use ONLY as a distress beacon by the US Coast
Guard and NOAA. Under no circumstance should this
frequency band be part of the pre-programmed oper-
ating frequencies of this radio.
Part15.21:Changesormodicationstothisdevicenotex-
pressly approved byVertexStandardcould void theusers
authorizationtooperatethisdevice.
List of the practicable area
AUT BEL BGR CYP CZE DEU
DNK ESP EST FIN FRA GBR
GRC HUN IRL ITA LTU LUX
LVA MLT NLD POL PRT ROU
SVK SVN SWE CHE ISL LIE
NOR
ThisdevicecomplieswithPart15oftheFCCrules.Opera-
tionissubjecttotheconditionthatthisdevicedoesnotcause
harmfulinterference.
The
VX-230
provide
[
Side 1
]
and
[
Side 2
]
keys. These Pro-
grammable(
PF
)keysfunctionscanbecustomized(settoother
functions), viaprogramming by your
VERTEX STANDARD
dealer, to meet your communications/network requirements.
Some features may require the purchase and installation of op-
tional internal accessories. The possible
PF
key features are
illustrated below, and their functions areexplained in thenext
chapter.Forfurtherdetails,contactyour
VERTEX STANDARD
dealer.
Forfuturereference,checkthe boxbelow toeachfunctionthat
has been assigned to the
PF
key on your particular radio, and
keepithandy.
functiOn
Programmable Key
[
Press / Press & Hold
]
functiOn
Programmable Key
[
Press / Press & Hold
]
[
Side 1
] [
Side 2
] [
Side 1
] [
Side 2
]
None / / TA
(
Talk Around
)
/ /
Mon
(
Monitor
)
/ / TX Save Disable / /
SQL Off / / Reset / /
SQL Set / / Call / /
Low Power / / Call 2 / /
Scan / / Call 3 / /
Follow-Me Scan / / Speed Dial / /
Scan Set / / Lock / /
DW
(
Dual Watch
)
/ / Emergency
/
/
TA Scan / /
Lone Worker
/
/
mOdel reference
mOdel freQuency tX POwer
VX-231-D0-5 134 - 174 MHz 5W
VX-231-G6-5 400 - 470 MHz 5W
VX-231-G7-5 450 - 520 MHz 5W
Warranty pOliCy
Vertex Standardwarrants, tothe originalpurchaser only,its
Vertex Standard manufacturedcommunications products
againstdefectsin materialsand workmanshipunder normal
useandservice foragiven periodof timefromthe dateof
purchase.
LimitedWarrantyDetails:
NorthAmericacustomers(USAandCanada):
http://www.vertexstandard.com/lmr/warranty-terms.aspx
CustomersoutsideofNorthAmerica:
Contacttheauthorizeddealerinyourcountry.
Copyright 2013
Vertex Standard LMR, Inc.
All rights reserved.
Printed in China
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vertex Standard VX-231 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vertex Standard VX-231 in the language / languages: English as an attachment in your email.

The manual is 0,56 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info