622303
5
Zoom out
Zoom in
Previous page
1/53
Next page
DVM9912 VELLEMAN
5
NOTE: In some low AC and DC voltage ranges, with the test leads not connected to a device, the display may
show a random, changing reading. This is normal and is caused by the high input sensitivity. The
reading will stabilise and give a proper measurement when connected to a circuit.
MODE BUTTON
To select Diode/Continuity, DC/AC, Hz/%Duty
RANGE BUTTON
When the meter is turned on for the first time, it automatically goes into Autoranging mode. This mode
automatically selects the best range for the measurements and is generally the best mode for most
measurements. For measurements situations that require a manually selected range, perform the following
actions:
1. Press the RANGE button. The “AUTO” indication on the display will disappear.
2. Press the RANGE button to go through the available ranges and you select the range you want.
3. Press and hold the RANGE button for 2 seconds to exit the ManualRanging mode and return to
AutoRanging.
DATA HOLD BUTTON
The data hold function allows the meter to “freeze” a measurement for later reference.
1. Press the DATA HOLD button to freeze the reading on the display. The indicator “HOLD” will appear on the
display.
2. Press DATA HOLD again to return to normal operation.
RELATIVE BUTTON
The relative measurement feature allows you to make measurements relative to a stored reference value. A
reference voltage, current, etc. can be stored and measurements made in comparison to that value. The
displayed value is the difference between the reference value and the measured value.
1. Perform any measurement as described in the operating instructions.
2. Press the RELATIVE button to store the reading in the display and the “REL” indicator will appear on the
display.
3. The display will now indicate the difference between the stored value and the measured value.
4. Press the RELATIVE button to return to normal operation.
7. Measurements
DC VOLTAGE MEASUREMENTS
CAUTION:
Do
not measure DC voltages if a motor on the circuit is being switched ON or OFF. Large
voltage surges may occur that can damage the meter.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Velleman DVM9912 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Velleman DVM9912 in the language / languages: English, German, Dutch, French, Spanish as an attachment in your email.

The manual is 1,16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info