622294
4
Zoom out
Zoom in
Previous page
1/55
Next page
DVM68
25.02.2011
4
3. Safety Instructions
Read this manual thoroughly. Familiarise yourself with the functions of the device
before actually using it.
Only use the device for its intended purpose. Using
the device in an unauthorized
way will void the warranty. Damage caused by disregard of certain guidelines in this
manual is not covered by the warranty and the dealer will not accept responsibility
for any ensuing defects or problems.
Follow the instr
uctions below to guarantee a safe use of the meter and all its
functionalities.
During use of the meter, respect all directives concerning protection against
electroshocks and misuse. Never exceed the indicated limits.
WARNING: To avoid electrical shock always
disconnect the test leads prior to
opening the housing.
Remark: refer to the warning on the back of the meter
WARNING: To prevent fire, use exact fuses.
Remark: refer to the warning on the back of the meter
Keep the device away from children and unauthorised users.
Protect this device from shocks and abuse. Avoid brute force when operating.
Avoid cold, heat and large temperature fluctuations. When the unit is moved from a
cold to a warm location, leave it
switched off until it has reached room temperature.
This to avoid condensation and measuring errors.
This is an installation category CAT III 600V / CAT II 1000V measuring
instrument. Never
use this equipment in a higher category than indicated. Refer t
§4 Overvoltage /installation category.
Pollution degree 2-
device. For indoor use only. Keep this device away from rain,
moisture, splashing and dripping liquids. Not for industrial use.
Pollution degree.
Before each use, make sure the test probes are in good condition.
fingers behind the protective edges of the test probes while measuring!
touch free terminals when the meter is connected to a circuit.
Make sure the meter is in t
he appropriate measuring range before connecting it to a
test circuit.
Risk of electric shock during operation.
Be very careful when measuring live
circuits.
Use extreme caution when measuring voltages higher than 60Vdc or 30Vac
rms.
Do not measure circuits that may contain voltages > 1000V
Do not measure current in circuits with voltages > 250V
Do not conduct resistance, diode-
or continuity measurements on live circuits.
When measuring currents above 5
A, max. 15s continuous measurement
a 10 minutes break between 2 measurements.
When carrying out measurements on a TV set or switching power circuits, always be
aware that high amplitude voltage pulses at the test points might damage the
meter.
Do not replace internal parts
yourself. Replace damaged or lost accessories by
identical ones with the same specifications. Order spare accessories e.g. test probes
at your dealer.
Rev. 01
©Velleman nv
Read this manual thoroughly. Familiarise yourself with the functions of the device
the device in an unauthorized
way will void the warranty. Damage caused by disregard of certain guidelines in this
manual is not covered by the warranty and the dealer will not accept responsibility
uctions below to guarantee a safe use of the meter and all its
During use of the meter, respect all directives concerning protection against
disconnect the test leads prior to
Protect this device from shocks and abuse. Avoid brute force when operating.
Avoid cold, heat and large temperature fluctuations. When the unit is moved from a
switched off until it has reached room temperature.
This is an installation category CAT III 600V / CAT II 1000V measuring
use this equipment in a higher category than indicated. Refer t
o
device. For indoor use only. Keep this device away from rain,
moisture, splashing and dripping liquids. Not for industrial use.
Refer to §5
Before each use, make sure the test probes are in good condition.
Always place your
fingers behind the protective edges of the test probes while measuring!
Never
touch free terminals when the meter is connected to a circuit.
he appropriate measuring range before connecting it to a
Be very careful when measuring live
Use extreme caution when measuring voltages higher than 60Vdc or 30Vac
or continuity measurements on live circuits.
A, max. 15s continuous measurement
followed by
When carrying out measurements on a TV set or switching power circuits, always be
aware that high amplitude voltage pulses at the test points might damage the
yourself. Replace damaged or lost accessories by
identical ones with the same specifications. Order spare accessories e.g. test probes
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Velleman DVM68 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Velleman DVM68 in the language / languages: English, German, Dutch, French, Spanish as an attachment in your email.

The manual is 0,9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info