665293
2
Zoom out
Zoom in
Previous page
1/56
Next page
Table of contents
2 Installation instructions VRC 470f 0020124645_00
Table of contents
1 Notes on the installation instructions ..............4
1.1 Observing other applicable documents ................4
1.2 Document storage ......................................................4
1.3 Symbols used ...............................................................4
1.4 Applicability of the instructions ..............................4
1.5 CE label .........................................................................4
1.6 Glossary.........................................................................4
2 Safety ............................................................................5
2.1 Safety and warning information .............................5
2.1.1 Classification of warnings .........................................5
2.1.2 Structure of warnings ................................................5
2.2 Intended use ................................................................5
2.3 Basic safety instructions ...........................................5
2.4 Requirements for cables ...........................................6
2.5 Directives, laws and standards ................................6
3 System description ..................................................7
3.1 System design ..............................................................7
3.2 Functionality.................................................................7
3.3 Appliance design .........................................................8
3.4 Identification plate .....................................................8
3.5 Accessories ...................................................................8
4 Installation ..................................................................9
4.1 Checking the delivery ................................................9
4.2 Requirements for the installation site ...................9
4.2.1 Radio receiver unit .....................................................9
4.2.2 Controller ......................................................................9
4.2.3 Outside temperature sensor/transmitter ..............9
4.3 Fitting the radio receiver unit in the boiler ..........9
4.4 Wall-mounting the radio receiver unit ................. 10
4.4.1 Removing the radio receiver unit from the
wall-mounting base .................................................. 10
4.4.2 Secure the wall-mounting base to the wall ..........11
4.4.3 Fitting the radio receiver unit ..................................11
4.5 Fitting the outside temperature sensor/
transmitter ...................................................................11
4.6 Fitting the controller .................................................13
5 Electrical installation .............................................14
6 Start-up .......................................................................15
6.1 Overview of Installation assistant set-up
options ..........................................................................15
6.2 Making settings for the operator ...........................16
6.3 Setting other parameters for the heating
system ..........................................................................16
7 Operation ....................................................................17
7.1 Overview of menu structure ...................................18
7.2 Overview of Installer level ..................................... 20
8 Description of functions ....................................... 27
8.1 Service information ..................................................27
8.1.1 Entering contact details ..........................................27
8.1.2 Entering the service date .......................................27
8.2 System configuration: System ...............................27
8.2.1 Reading the system status .....................................27
8.2.2 Reading the water pressure of the heating
system .........................................................................27
8.2.3 Reading the DHW heating status ..........................27
8.2.4 Reading the collector temperature ......................27
8.2.5 Setting the frost protection delay ........................28
8.2.6 Setting the pump blocking time ...........................28
8.2.7 Setting the maximum preheating time ...............28
8.2.8 Setting the maximum pre-switch-off time ..........28
8.2.9 Setting the temperature threshold for
constant heating .......................................................28
8.2.10 Setting the raising temperature ............................29
8.2.11 Reading the software version ................................29
8.2.12 Configuring the heating circuit .............................29
8.3 System configuration: Heat generator ................29
8.3.1 Reading the status of the heat generator ..........29
8.3.2 Reading the value of the VF1 temperature
sensor ..........................................................................29
8.3.3 Activating the low loss header .............................29
8.4 System configuration: HEATING 1 and, if
relevant, HEATING 2 .................................................29
8.4.1 Activating the heating circuits .............................29
8.4.2 Reading the end of the current time period ......29
8.4.3 Setting the target room temperature ................. 30
8.4.4 Reading the current room temperature............. 30
8.4.5 Setting the set-back temperature (set-back
temp.) .......................................................................... 30
8.4.6 Reading the target flow temperature ................. 30
8.4.7 Reading the current flow temperature............... 30
8.4.8 Reading the status of the heating circuit
pump ........................................................................... 30
8.4.9 Reading the status of the heating circuit
mixer valve ................................................................ 30
8.4.10 Activating room temperature control ............... 30
8.4.11 Activating automatic summer time detection .. 30
8.4.12 Setting the heating curve ........................................31
8.4.13 Setting the minimum flow temperature for
heating circuits ...........................................................31
8.4.14 Setting the maximum flow temperature for
the mixing circuit .......................................................31
8.4.15 Reading the status of advanced functions ..........31
8.4.16 Specifying control modes outside time
periods ..........................................................................31
8.5 System configuration: Domestic hot water ........32
8.5.1 Setting the target temperature for domestic
hot water cylinder (desired hot water
temperature) .............................................................. 32
8.5.2 Reading the current temperature of the
domestic hot water cylinder ..................................32
8.5.3 Reading the status of the cylinder charge
pump ............................................................................32
2


Need help? Post your question in this forum.

Forumrules
1

Forum

vaillant-vrc-470f

Reset search

  • How can one test if a VR20 outside temp. sensor is working? If pressing the Red button on the rear of the module does not activate the flashing green light. is this an indication of faulty unit? The lens is clean. Solar sensor charging at around 2.1 volts. Battery is at 3volts. Submitted on 29-12-2021 at 16:45

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant VRC 470F at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant VRC 470F in the language / languages: English as an attachment in your email.

The manual is 1,72 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info