13
Technische gegevens 9
uniSTOR - VIH Q 120, 150, 200 13
BE
Apparaatbenaming Eenheden VIH Q 120 VIH Q 150 VIH Q 200
reservoirinhoud (nominaal) l 115 150 200
toegel. bedrijfsoverdruk voor warmwatertemperatuur bar 10 10 10
toegel. bedrijfsoverdruk voor verwarmingswater bar 10 10 10
max. toegel. warmwatertemperatuur °C 85 85 85
max. toegel. verwarmingswatertemperatuur °C 110 110 110
continu vermogen warm water
1)
l/h (kW) 615 (25) 640 (26) 837 (34)
uitgangsvermogen warm water
1)
l/10 min 145 195 250
vermogenskarakteristiek N
L
1)
–1,02,03,5
verwarmingsoppervlak m
2
0,84 0,90 1,18
inhoud van de verwarmingsspiralen l 5,9 6,2 8,1
gemiddelde verwarmingsstroom (nominaal)
3)
m
3
/h 1,6 1,6 1,6
drukverlies bij gemiddelde verwarmingsstroom (nom.) mbar 50 50 65
stand-by energieverbruik
2)
kWh/24h 1,2 1,3 1,6
koudwateraansluiting schroefdraad R
3
/
4
R
3
/
4
R
3
/
4
warmwateraansluiting schroefdraad R
3
/
4
R
3
/
4
R
3
/
4
circulatieaansluiting schroefdraad R
3
/
4
R
3
/
4
R
3
/
4
toevoer- en terugloopaansluiting schroefdraad R 1 R 1 R 1
hoogte mm 850 1063 1333
Breedte mm 585 585 585
Diepte mm 590 590 590
gewicht leeg kg 80 95 115
1) Vastgesteld volgens DIN 4708, deel 3
2) Bij een T tussen ruimte- en warmwatertemperatuur van 40 K
3) Met reservoirlaadset
9 Technische gegevens
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant VIH Q 120-2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant VIH Q 120-2 in the language / languages: Dutch as an attachment in your email.

The manual is 0,94 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info